ADS Environmental Services ADS TRITON+ QR 775027 A3 User Manual

Page 389

Advertising
background image

A-8

ADS TRITON+ Manual

Surface Velocity

Accuracy

+/- 0.25 feet per second (0.08 m/s) or 5% of the
actual reading (whichever is greater) in flow
velocities from 1.00 to 15.00 ft/sec (0.30 to 4.57
m/s)

Note: Flow conditions may cause the designated
accuracy to vary and hinder or prevent the
effective use of surface velocity technology.

Deadband

3 inches (76 mm) from the bottom of the rear,
descended portion of the sensor

Minimum

Velocity

1 foot per second (0.30 m/sec)

Frequency

Varies based on the parameter settings

Range

3 to 42 inches (7 to 1067 mm)

Resolution

0.01 feet per second (0.003 m/sec)

Surcharge Peak Velocity

Range

-30 to 30 feet/second (-9.1 to 9.1 m/sec)

Frequency

250 kHz

Resolution

0.01 feet per second (0.003 m/sec)

Accuracy

+/- 0.2 ft/sec (0.06 m/sec) or 4% of actual peak
velocity (whichever is greater) in flow velocities
from -5 to 20 ft/sec (-1.52 to 6.10 m/sec)

Advertising