6-68 ADS TRITON+ Manual

Editing the XIO Device

Use the following information to configure the externally powered
XIO

device for the TRITON+ monitor for up to two analog

inputs, two analog outputs, two digital inputs and two digital
outputs:

XIO Device properties dialog

Note: There is a single XIO device limit per TRITON+.

Analog Input 1 (2) Configure the values in this section to specify
how to process the incoming analog signal from an analog device
connected to the XIO device.

Entity Select the entity type corresponding to the incoming
analog signal to ensure the correct unit of measure is applied to
the resulting data. The XIO device supports the following
analog inputs: depth (DEPTH_A1), velocity (VEL_A1),
quantity (Q_A1), temperature (TMP_A1), PH (PH_A1), as
well as a generic analog input (AI_A1). For example, choose
DEPTH_A1 to record incoming analog depth values to a
DEPTH_A1 entity which uses corresponding units of measure
in inches (or millimeters).