Special Conditions for Safe Use
During the ATEX/IECEx/CSA approval process, certain conditions
are set forth that must be observed when using the certified
equipment. These Special Conditions for Safe Use can be found in
the body of each certification (referenced in this manual), as well as
on a page attached to the Declaration of Conformity. Following is a
summary of these Safe Use Instructions:
Parts of the enclosure may be non-conducting and may generate
an ignition-capable level of electrostatic charge under certain
extreme conditions. Therefore, do not install this equipment in
a location where it may be subject to external conditions (such
as high-pressure steam or dust) that may cause a buildup of
electrostatic charge on non-conducting surfaces.
As aluminum is used at the accessible surface of this unit, in the
event of rare incidents, ignition sources due to impact and
friction sparks may occur. This shall be considered when it is
being installed, particularly in locations that require equipment
with a Group II Ga level of protection.
The equipment (ADS Model 8000-FST-IM) shall be used in
the hazardous area only when fully assembled. Do not perform
any maintenance of internal parts, replacement of battery packs,
or replacement of fuses unless the unit is located in a safe area.
Applicable to the USB Serial Interface : Measures shall be
taken to limit transient over voltages to the USB Serial
Interface to an appropriately low level in accordance with
Overvoltage Category 1 (IEC 60664-1).
The equipment shall be installed as per installation drawing
8000BK0009.
The External Power and Communications Unit (ExPAC) may
only be mounted in a non-hazardous location.
The IS Modem DAA is only permitted to be connected to a
“Public Switched Telephone Network”.