ADS Environmental Services ADS TRITON+ QR 775027 A3 User Manual

Page 396

Advertising
background image

Specifications

A-15

Digital Inputs

Two-switch, solid state, or dry contact inputs

Input impedance: 4.7 Kilo-ohms

Digital Outputs

Two SPST Relays

Maximum Load: 2 A @ 250 VAC, 2A @ 30 VDC

Minimum Load: 5 VDC, 20 mA

External

Power/Comm

Unit

ADS ExPAC (Refer to page A-11 for
specifications and details on the ExPAC
)

Connectors

Three cable glands for power cable, monitor
communication cable, and digital and/or analog
I/O cable, NEMA4X/IP66 protection

5.2-mm DIN rail terminal blocks for I/O
connection (30- to 12-gauge wire size)

Certification

Associated Apparatus certification for use with
approved equipment in Zone 0 (Class I, Division
1, Groups C & D, in the U.S.) and CSA Class I,
Zone 0, IIB

Sira 09ATEX2027X, IECEX SIR09.0020X, CSA
2013 2671180