ADS Environmental Services ADS TRITON+ QR 775027 A3 User Manual
Page 396

Specifications
A-15
Digital Inputs
Two-switch, solid state, or dry contact inputs
Input impedance: 4.7 Kilo-ohms
Digital Outputs
Two SPST Relays
Maximum Load: 2 A @ 250 VAC, 2A @ 30 VDC
Minimum Load: 5 VDC, 20 mA
External
Power/Comm
Unit
ADS ExPAC (Refer to page A-11 for
specifications and details on the ExPAC)
Connectors
Three cable glands for power cable, monitor
communication cable, and digital and/or analog
I/O cable, NEMA4X/IP66 protection
5.2-mm DIN rail terminal blocks for I/O
connection (30- to 12-gauge wire size)
Certification
Associated Apparatus certification for use with
approved equipment in Zone 0 (Class I, Division
1, Groups C & D, in the U.S.) and CSA Class I,
Zone 0, IIB
Sira 09ATEX2027X, IECEX SIR09.0020X, CSA
2013 2671180