6-22 ADS TRITON+ Manual
Note: The velocity parameters corresponding to the Peak
Combo Sensor typically should not require editing.
However, if modifications are necessary, ADS does not
recommend making changes to these parameters without
proper training or assistance.
Note: When using a Peak Combo Sensor and Surface
Combo Sensor at the same monitoring point, ADS
recommends maintaining the same settings for all of the
parameters corresponding to both Peak Velocity (Velocity
tab on the Edit Peak Combo Parameters dialog) and
Surcharge Peak Velocity (Peak Velocity tab in the Edit
Surface Combo Parameters dialog) to ensure consistency
between the velocity readings.
Enable Select this checkbox to ensure the monitor begins
taking velocity readings at the designated interval once
activated. This option is selected by default.
Flow Type Select the option that best reflects the kind of
flow conditions that typically occur at the monitoring point
from the drop-down list:
Typical Flow exhibits a typical diurnal pattern. This is
the default setting.
Wet/Stagnant Flow remains in the pipe, but moves only
during wet weather events.
Usually Dry Pipe typically remains dry, except under
wet weather conditions.
Sensitivity Select the appropriate velocity sensor sensitivity
from the drop-down list. A sensitivity that is too high may
produce noise, causing interference in the signal and resulting
in spikes in the data. A sensitivity that is too low can produce
readings that are low in comparison with confirmation readings.
The default sensitivity is 10.