SLIDING ADAPTER BRACKET

SENSOR MOUNTING PLATE

SURFACE COMBO/ULTRASONIC DEPTH SENSOR

PREVIOUS VERSION OF

Attaching the Surface Combo Sensor or Ultrasonic Depth Sensor to the

Sliding Adapter Bracket

12. Confirm the sensor is still level. To protect the crystals on the

sensor, use a block of wood of uniform dimensions between the
level and the flat face of the horizontal, ultrasonic depth sensor
portion of the sensor!

13. Determine the physical offset for the Surface Combo Sensor or

Ultrasonic Depth Sensor by measuring the distance from the
crown (top) of the pipe to the face of the sensor (horizontal
surface with the two ultrasonic crystals on either sensor). This
value is required when configuring the monitor using the Qstart
software. Do not measure in reference to the the angled
surface velocity or surcharge velocity portions of the sensor
.