Kontron CG1200 Carrier Grade Server User Manual

Page 100

Advertising
background image


94

Kontron CG1200 Carrier Grade Server Installation and Maintenance Guide 94

Table 7. System Status LED Definitions

Color

State

Criticality

Description

Green

Solid on

System OK

System booted and ready

Green

Blink

Degraded

System degraded:

•

Non-critical temperature threshold asserted

•

Non-critical voltage threshold asserted

•

Non-critical fan threshold asserted

•

Fan redundancy lost, sufficient system
cooling maintained. This does not apply to
non-redundant systems.

•

Power supply predictive failure

•

Power supply redundancy lost. This does
not apply to non-redundant systems.

•

Corrective errors over a threshold of 10 and
migrating to a mirrored DIMM (memory
mirroring). This indicates the user no longer
has spare DIMMs indicating a redundancy
lost condition. The corresponding DIMM
LED should light up

Amber

Blink

Non-critical

Non-fatal alarm – system is likely to fail:

•

Critical temperature threshold asserted

•

CATERR asserted

•

Critical voltage threshold asserted

•

VRD Hot asserted

•

SMI timeout asserted

Amber

Solid on

Critical, non-
recoverable

Fatal alarm – system has failed or shut down

•

CPU missing

•

Thermal Trip asserted

•

Non-recoverable temperature threshold
asserted

•

Non-recoverable voltage threshold asserted

•

Power fault/power control failure

•

Fan redundancy lost, insufficient system
cooling. This does not apply to non-
redundant systems.

•

Power supply redundancy lost, insufficient
system power. This does not apply to non-

Advertising