Kontron CG1200 Carrier Grade Server Installation and Maintenance Guide 96

Table 8. POST Error Beep Codes

Beeps

Error Message

Post Progress Code

Description

1

USB device
action

N/A

Short beep sounded whenever a USB device is discovered
in POST or inserted or removed during runtime

1

Intel® TXT
security violation

0xAE, 0xAF

System halted because the Intel® Trusted Execution
Technology detected a potential violation of system
security

3

Memory error

Multiple

System halted because a fatal error related to the memory

was detected

The following Beep Codes are sounded during BIOS recovery

2

BIOS Recovery
started

N/A

Recovery boot has been initiated

4

BIOS Recovery

failure

N/A

BIOS recovery has failed. This typically happens so quickly

after recovery is initiated that it sounds like a 2 – 4 beep
code.

The Integrated BMC may generate beep codes upon detection of failure conditions. Beep codes are sounded each
time the problem is discovered, such as on each power-up attempt, but are not sounded continuously. Codes that are
common across all Intel server boards and systems that use the same generation chipset are listed in the following
table. Each digit in the code is represented by a sequence of beeps whose count is equal to the digit.

Table 9. Integrated BMC Beep Codes

Beep
Code

Reason for Beep

Associated Sensors

1-5-2-1

CPU socket population error

CPU1 socket is empty or sockets are populated
incorrectly
CPU1 must be populated before CPU2

1-5-2-4

MSID mismatch

MSID mismatch occurs if a processor is installed into a
system board that has incompatible power capabilities

1-5-4-2

Power fault

DC power unexpectedly lost (power good dropout)
Power unit sensors report power unit failure offset

1-5-4-4

Power control fault

Power good assertion timeout
Power unit sensors report soft power control failure
offset

1-5-1-2

VR watchdog timer

VR controller DC power on sequence was not
completed in time

1-5-1-4

Power supply status

The system does not power on or unexpectedly powers
off and a Power Supply Unit (PSU) is present that is an
incompatible model with the other PSU in the system.