Kontron CG1200 Carrier Grade Server Installation and Maintenance Guide 18

NOTE: The server does not have to be powered down just to remove the front bezel.

1. Loosen the captive bezel retention screw on the right side of the bezel (Figure 10, “A”).

2. Rotate the bezel to the left to free it from the pins on the front panel, (“B”) and remove it.

Figure 10: Removing the Front Bezel

3.2.4 Re-Installing the Front Bezel

1. Insert the tabs on the left side of the bezel into the slots on the front panel of the chassis.

2. Move the bezel toward the right and align it around the control panel and the USB ports.

3. Tighten the retention screw to secure the bezel. (Torque to 8lbf*in)

3.2.5 Removing the Riser Card Assembly

The riser card assembly has to be removed from the chassis to perform tasks such as:

Replacing a riser card

Installing or replacing a PCI add-in card

Installing or replacing a hardware RAID controller

Working with any components on the server board that are near the riser card assembly, such as the
CPU2 DIMMs, an I/O module, or an RMM4 card

Replacing the server board

To remove the riser card assembly:

1. Power down the server and remove all external devices and the power cord(s)