Kontron CG1200 Carrier Grade Server User Manual

Page 28

Advertising
background image


22

Kontron CG1200 Carrier Grade Server Installation and Maintenance Guide 22

5.

Using both hands, push down firmly and evenly on both sides of the DIMM until it snaps into place and

the levers close.(“C”)
IMPORTANT: Visually check that each latch is fully closed and correctly engaged with the notch on
the DIMM edge. (“D”)

6.

Replace the riser card assembly and the chassis cover if you have completed all work inside of the

server.

Figure 12: Memory DIMM Installation

3.3.4 Replacing or Removing Memory DIMMs

NOTE: To reduce the risk of electrostatic discharge (ESD) damage to the processor or the DIMM, use a
ground strap attached to the front panel (with the bezel removed).

To remove a DIMM from the S2400EP4 server board, follow these steps:

1.

Power down the server and remove all peripheral devices and the power cord(s)

2.

Remove the chassis cover. For instructions, see Section 3.2.1, “Removing the Cover”.

3.

Open the DIMM slot levers for the DIMM you want to remove. ()

4.

Using both hands, hold the DIMM by the edges and lift it up from the slot. Store the DIMM in an anti-

static package.

5.

If you are installing a replacement DIMM in this slot, return to Step 5 in “ Installing Memory DIMMs”.

Otherwise, replace the chassis cover if you have completed all work inside the server. See Section
3.2.2, “Re-installing the Chassis Cover” for instructions.