3. Align the tabs on the bottom of the SuperCap module with the mating connectors on the bracket and

slide the module to the right to secure the SuperCap module to the bracket (Figure 36, “A”).

4. Fasten the SuperCap module to the bracket with the module retention screw (“B”) to ensure that the

module does not disengage from the bracket. (The retention screw will only tighten in place if the
module is properly installed in the bracket.)

Figure 36: Fastening the SuperCap Module to the Bracket

5. If the alarms cable from the TAM board is in the way, disconnect the cable and move it out of the way.

If the front panel power cable is in the way, disconnect the cable from the FPB and move it out of the
way.
(See 4.1.3, “ Cable Routing Reference” for the cable connector locations)