No commands (simple access), With commands – Interlogix Monitor XL Hardware Guide User Manual

Page 10

Advertising
background image

6

Monitor ISM/xL™ Hardware Guide

22-0375 rev1.1

No Commands (Simple Access)

Door Mode

<Login>

Notes

Card Only

<card>

If a UID/PIN is entered, it will be ignored

Card & PIN

<card> <pin>

UID is not required since the card
automatically identifies the <uid>

Card or UID/PIN

<card> or <uid> <pin>

UID/PIN Only

<uid> <pin>

If card is presented, it will be ignored.

<uid> – User ID


With Commands

Door Mode

<cmd> <Login>

Notes

Card Only

<cmd> <card>

If a UID/PIN is entered, it will be ignored

Card & PIN

<cmd> <card> <pin>

Card badging must always be done before
the PIN entry.

Card or UID/PIN

<cmd> <card> or

<cmd> # <uid> <pin>

Pressing “#” is required between the
command and uid/pin entry.

UID/PIN Only

<cmd> # <uid> <pin>

Pressing “#” is required between the
command and uid/pin entry. (Note

<cmd> # <pin> in PIN Only systems)

<cmd> – Command

NOTES:
<login> requires your <card> OR alternatively, your uid/pin.
E.g. <3 digit UID> <4 digit PIN>. Leading zeros cannot be omitted in UID or PIN.
Example 1: Arm area using card – enter < 3 card >
Example 2: Work late for 3 hours using uid/pin – enter < 6 3 # 001 1234 > for user 001 with pin 1234
Example 3: Access area without using card – enter < 001 1234 > for user 001 with pin 1234.

Using Duress Pin at Arming Station

A Duress Pin (reversing last 2 digits of a user’s pin entered on the keypad to transmit a potential hold-up
condition) can be used at an Arming Station if the duress feature has been enabled in the System Group.

LED Indicators
Work Late LED

Turns on if the area the Arming Station is assigned to is scheduled.

Turns on solid 15 minutes before scheduled closing time.

Does not operate if the area is not scheduled.

Door State LED

Solid red if the door is locked.

Solid green if the door is unlocked.

Flashing red during disarming if there had been an alarm in the area.

Armed LED

When activated, armed LED only stays on for the duration of the area’s Entry/Exit Delay during the following area
arming state changes.

Momentarily solid green when the area is disarmed to OFF.

Momentarily solid red when the area is armed to STAY.

Momentarily flashing red when the area is armed to Fully ON.

Arming Station Internal Buzzer Indications

Entry/Exit tones same as LCD keypad.

Fire Siren – intermittent tone.

Burglary Siren – steady tone.

Bad Command Entry – double short beeps.

Command accepted – single long beep.

Unauthorized to perform command – double long beep.

Advertising