First elevator connections to 2 elevator module, 2 elevator module, Monitor ism/xl™ hardware guide 37 – Interlogix Monitor XL Hardware Guide User Manual

Page 41

Advertising
background image

22-0375 rev1.1

Monitor ISM/xL™ Hardware Guide

37

(+)12V

(

-

)0V

Data B

Data A

14

3

2

1

4

3

2

5

6

1

3

2

1

4

3

2

1

4

3

2

(+)

12V

(

-

)0

V

D

a

ta

A

D

a

ta

B

N.

O

.

Com

.

N.

C

.

Com

.

N.

O

.

Co

m

m

o

n

Co

m

m

o

n

(+

)5

/1

2

V

D

C

G

ree

n

LED

Re

d LED

Gr

ou

nd 0V

This Module Bus
connector is for
connecting a
Service LCD
Keypad Module

bl

ac

k

ye

llo

w

re

d

gr

ee

n

1

3

2

12

12

N.

O

.

Co

m.

N.

C.

Co

m.

N.

O

.

Com

m

on

By

p

a

s

s

Fi

re

B

y

p

a

ss

Co

mm

o

n

(+

)5

/1

2

V

DC

G

ree

n

LED

R

ed

LED

R

ead

er

1 D

a

ta 1

Gr

ound

0

V

R

eade

r 1

Dat

a

0

P

a

ni

c

I

n

pu

t

1

4

3

2

5 6

1

3

2

1

4

3

2

1

3

2

1 2

1 2

Re

ade

r 2

Dat

a

0

Re

ade

r 2

Dat

a

1

XXXXX

1

st

El

ev D

a

ta I

n

2 Elevator

Module

Self resetting
0.5A fuse.

Low Voltage
LED

Processor OK LED

(normal = slow flash)

Unlock Relay
2 LED

Auxiliary Relay 2 LED

Module Bus communications
indicator LED

Auxiliary
Relay 1 LED

Unlock Relay
1 LED

Reader

Reader

Aux
Rly 2

Aux
Rly 1

Unlock
Rly 1

Unlock
Rly 2

2

nd

El

ev D

a

ta

In

Not Used

Not Used

By

pa

s

s

Fi

re

B

y

p

a

ss

Pani

c

Inp

u

t

Module Bus

5V

12V

Reader Voltage

Jumper

5V

12V

Reader Voltage

Jumper

P/N 650-9017

5 digit serial
number to program
in Module
Programming

red

orange

white

green

black

READER
for
Elevator
Module’s
first
elevator

brown

not used

1

3

2

1

3

2

1 2

1

4

3

2

5

1
2

13
2

RLY1

RLY2

(+)
(

-

)

DATA

DA

T

A

DAT

A

0

DAT

A

1

Elevator

Relay Board

Aux
12VDC

(+

)

P

/N

6

50-

90

35

C

u

ta

w

a

y vi

ew

Ea

rt

h

Co

m

m

o

n

Gree

n

LED

R

ead

er 1/

2 D

a

ta

1

R

ead

er 1/

2 D

a

ta

0

El

ev

1/2

Da

ta

0

E

le

v

1

/2 D

a

ta

In

By

pas

s

P

ani

c

In

0V

Neg

(

-

)

(+)

12VD

C

Grou

nd 0V

Com

m

on

By

pas

s

F

ire

B

y

pas

s

Com

m

on

T

a

mpe

r Ou

tput

Gr

een

L

E

D

Rea

der

1/2

Dat

a

1

R

e

a

der

1/2

Dat

a

0

Pan

ic

Ou

t

El

ev

1

/2 D

a

ta

0

El

ev

1

/2 D

a

ta

1

El

e

v

1/2 Dat

a

In

12

VDC

12V

DC

Gro

und

0

V

P/N

641

-9

0

3

6

12

12

12

3

2

1

4

3

2

1

4

3

2

1

1 2

1 2

1 2

3

2

1

3

2

1

4 5 6

3

2

1

4 5

3

2

1

4 5

(

-

) (+)

(+)

(

-

)

El

ev

1/2

Da

ta 1

(+

) 5

/ 1

2

V

D

C

S

par

e

Com

m

on

TB1

TB

1

0

TB4

TB9 TB7

TB3 TB2

TB

1

3

TB14

TB

11

TB12

TB

16

TB

1

5

0V

N

e

g

0V

Neg

F

ire

By

pas

s

RS485 Reader
Connections for
reader runs over 500
ft.

See following

“Wiegand to RS485
Interface Board”

Reader Voltage
Jumper

Module Bus
connection
from the
motherboard
or paralleling
to another
Module

Power

Supply

(+)

( )

Power

Supply

(+)

( )

Relay and
Isolator board
cabinet 12VDC
power supply.

Module Bus

Elevator
Module
12VDC
Power
Supply must
also be
connected to
the Elevator
Module side
of its Isolator
boards.

Elevator
Module

Elevator
side

Elevator
Module
side

Elevator

Isolator

Board

( )

Au

x

12

V

D

C

Reader cable shield. Connect
to control unit ground lug.

Elevator Isolators and Relay boards do not have a 5 digit
serial # to program in Module Programming.

Parallel connections to next Elevator Relay board(s)

Power to next Elevator Relay board(s) in this cabinet only. NOTE: If more elevator
relay boards are added in additional expansion cabinets with their own power
supply - ALL RELAY BOARD’S POWER SUPPLY NEGATIVES MUST HAVE A
COMMON CONNECTION.

Fire Bypass is not intended for
"Life/Safety" applications.

2

nd

El

ev D

a

ta

0

2

nd

E

le

v

D

a

ta

1

1

st

El

ev D

a

ta

0

1

st

El

ev

D

a

ta

1

ELEVATOR MODULE and ISOLATOR BOARD (1

st

elevator connected to 2 Elevator Module)

First Elevator
Connections
to 2 Elevator
Module

Normal

RS485

Waterpipe ground input when a
cabinet ground lug is not available.
If quad cable is used, use all four
wires. Terminate two wires in #1
and two wires in #2, for
convenience.

5V

12V

Gr

oun

d

Earth Ground

T

a

m

per

Outpu

t

T

a

mpe

r Output

Elevator Module
current rating =

180mA

.

maximum.

Elevator
Isolator Board
current rating:
Elevator
Module
Connections
side =
100mA.
Elevator
Connections
side = 130mA
Plus add all
reader’s
current rating.

12

Tamper
Switch
Input

Not Jumper PINs.
Do not short.
Connect current
protected LED to
remote “Processor
OK LED”.

Not Jumper PINs.
Do not short.
Connect current
protected LED to
remote “LED
Always on When
Power OK”.

Advertising