8

Monitor ISM/xL™ Hardware Guide

22-0375 rev1.1

2 Zone Wiring

cont.


ORANGE Protection Point Input # 1

PURPLE Protection Point Input # 2

BLACK Input point
common connection.
Output power source
negative.

RED

GREEN

YELLOW

BLACK

"B"

Co

nn

ect

BLUE Switching to GND Output.

To output driven device.
E.g. electronic siren with
built in driver.

Input # 1 e.g. Main entrance door contact.
Programmed and wired as normally open
with 2.2K end of line resistor.

Input # 2 e.g. Motion detector alarm contact.
Programmed and wired as normally closed.

Protection Input points 1 & 2 and Output Wiring Example

(+)

(--)

2.2 K

NC

NO

CM

NC

NO

CM

Keypad
Base

(back view)

Power
Supply

(+)

(--)

Siren

Separate Data

A,B Cable

S

epar

ate

Po

w

e

r Ca

b

le

M
O
D
U
L
E

B
U
S

Common
Negative
Reference