22-0375 rev1.1

Communication Modules

Printer

Printer Serial Port Male DB25 Connector
(viewed from the connections side)

Pi

n

3 -

WH

IT

E

Pi

n 2

0

-

RED

Pi

n 5

- BR

OWN

P

in 7 -

B

L

AC

K

14

3

2

56

14

3

2

5

14

3

2

5

Tamper Pins

F1

1/2 AMP

P/N 342-3356

Bus communications
indicator

0V

CTS

RTS

RX

TX

Not

Us

ed

Printer

TB4

TB2

Printer Module

1

4

3

2

Module Bus

D

a

ta

A

D

a

ta

B

(+)

12V

0V

re

d

gr

ee

n

ye

llow

bl

ac

k

Current rating = 61mA

5 digit serial number
to program in Module
Programming

XXXXX

No

t Us

ed

TB3

PIN 1 - 13

PIN 14 - 25

Printer Programming
(using LCD Keypad only)
NOTE: The term “HSC” is used to access
the printer abilities in this application.

HSC is a proprietary communications of CSG
Security Inc. and not used in all markets.

This module has no inputs or outputs.

Enter the module’s 5-digit address in

Module programming.

Enable the tamper and make

input/output values “0”. Leave
defaulted to area 1 and leave all other
selections defaulted.

Press Save. Exit module programming

and then go back to module
programming and the same address.
This initializes the module.

Check Prn? (Printer) enabled: .

Screen changes to “HSC/Printer
Module Rebooting
”. Press OK. Return
to Printer programming screen.

Enter baud rate for printer:

0 = 1200, 1 = 2400, 2 = 4800,
3 = 9600, 4 = 19200.

If CTS is enabled ( ), only users with
authority to view History can start the
printer if it runs out of paper, etc. If it is
disabled ( ), simply fixing the printer
problem (e.g. load paper) will re-start
the printer. Press Save.

Printer Specifications
Type: RS232 serial 80 columns (or more)
Data Setup: 1 start bit, 1 stop bit, 8 data
bits, no parity, baud rate selectable
(recommend 1200), hardware
handshake.
Printer Connection: female DB25.

Settings for Epson LX300
(P/N 400-0810)
Character spacing = 10cpi, Shape of zero
= 0, Skip-over-perforation = Off,
Character table = PC 437, Auto line feed
= Off, Page length = 11 inches, Auto tear
off = Off, Tractor = Single, Interface =
Serial, Bit rate = 1200 bps (baud), Parity
= None, Data length = 8 bit, EXT/ACK =
On, Software = ESC/P, Auto CR = Off.

To start the Printer

Enter the History menu in the main

menus and select “Category” and
App” for application module.

Select “HSC”.

Select Printer or Lang for the

language the printer will print in.

When selecting printer press Start to

start the printer.

Press Pause to stop printing or
Resume to commence printing.

Press Cncl to cancel a backlog of

pending messages.

Press Plog to reprint the entire log in

the History menu.

Wiring Printer Connection to a PC
Serial Port
(TB 4: Printer Port)
(when the customer wants the history to
go directly to a computer instead of a
printer)

In the module settings, turn off the

CTS option in the Printer Menu.
In the terminal program (‘Terminal.exe’

in Windows for Workgroups; ‘Hyper
Terminal’ in Windows ’95/98) set the
baud rate for the same speed as the

module (typically 1200) and turn off

hardware flow control.

Only 2 connections are required:

Connect Tx on the module to Rx on

the PC serial port 9pin 3 on DB25;
pin 2 on DB9).

Connect OV/Gnd on the module to

0V/Gnd for the serial port (pin 7 on
DB25; pin 5 on DB9).

Refer to Installation Instructions P/N 22-0370 for further information.