Main control board – Interlogix Monitor XL Hardware Guide User Manual

Page 6

Advertising
background image

2

Monitor ISM/xL™ Hardware Guide

22-0375 rev1.1

Main Control Board

14

3
2

5

1

4

3

2

14

3

2

56

14

3

2

12

BATTERY

PLUG

(+)12V

(

-

)0V

Data B
Data A

bla

ck

red

3

14

3
2

14

3
2

14

3
2

14

3
2

3 1

3

1

1

3

1 2

2

2

2

3

12

Battery

F2

1 AMP

AU

X P

O

W

E

R

F3

1.5 AMP

TELEPHONE

1 A

M

P

MOD

U

L

E

B

U

S

F5

(+)

(

-

)

TAMPER

SPRING

36 pi

n

b

a

tt

e

ry

ba

ck

ed

ex

pa

n

s

ion RA

M

32 pin

E-prom

socket

COM

I/P

3

I/P

4

I/P

1

I/P

2

I/P

5

I/P

6

I/P

8

I/P

7

COM

COM

COM

MO

D

B

U

S

1

yello

w

gre

en

AC Input
16.5V, 40VA

(P/N 859-2246)

Au

x

12VDC

(+)

(+)

(

-

)

(

-

)

O/P2

O/P3 Siren

O/P1

O/P4

(+)12V

(

-

)0V

PH

O

N

E

L

INE

EARTH
GROUND

Seized Tip

Seized Ring

Ring

Tip

P

/N

34

2-3

3

5

0

P/N 342-3821

0V

B485

A485

GND/GND
CTS/RTS
RTS/CTS
DSR/DTR

DTR/DSR
TX/TX
RI/RI
CD/CD
RX/RX

P

C

/M

od

em

co

n

nec

tio

n

Short the upper left and
lower right silver pads.

R
A

M

Host RS485

Do not connect modules to this Module Bus connector
Reserved for Service use with LCD Keypad.

O/P Current Ratings
O/P1&4 = 10mA
O/P2 = 750mA
O/P3 = 1.8AMP

If using Station "Z" Quad cable for ground,
use all 4 conductors. Two wires can be
connected to terminal 1 and two to terminal 2.

(

-

)

(+)

KNOCK OUTS

CABLE

INLET

Use plastic 3/4 in. bushings
P/N 364-5100 to insert in knockouts
before bringing in cables.

Metal

En

c

los

ur

e

Main Control Board

TB1

TB4

TB2

TB

3

TB6

14

3

2

12

TB9

TB8

TB7

TB10

TB

1

6

TB

13

TB

1

2

TB

1

1

TB

1

4

TB

15

To Clear Memory

with no power to panel

J5

IN (default) for Non
Res. UL Fire
OUT for Res. UL Fire

TB5

Telco Off Hook

LED

Watchdog LED

Installation Notes for Further Reduction of RF Emissions
1. Terminating cables inside metal enclosure must never cross over the motherboard, behind
it or on top of it. Cables must run along the sides of the board.
2. Cables being brought into the box should come in through the "knock out" nearest the
terminal block it is being terminated at. E.g. A/C transformer cable should be brought in
through the knock out nearest the A/C termianl block. Avoid leaving long cable lengths around
the board or inside box.

micro-

processor

Fire
18V, 40VA

(P/N 859-0052)

HOST

P

O

RTS

18 AWG CONNECTION

CABLE REQUIRED

Siren & Battery
are fused
by a 1.8AMP
resetable fuse.

Resetable Fuse Notes
Will disconnect power if DC current
draw exceeds 1.8AMP.
WARNING: Very hot when
triggered: 120

°

C.

Disconnect battery for 1 min. to reset or,
silence siren. Hydro can stay connected.

See note
below.

P/N 936-6800

(7

50mA

max.

)

SIREN

M

O

DBUS

2

M

O

DBUS 2

MODBUS 1