Monitor ISM/xL™ Hardware Guide

22-0375 rev1.1

WW Modem and STU Interface “CPU Failure” available with main control module firmware 4.3 or greater.

CPU Failure

(WW Modem and STU)

Output 8 must be programmed as “System Fault” in System Outputs. Use Director Software outputs or Simplified or Advanced
(B000:00, System Outputs #56) keypad programming. For a negative to positive output, it can be left defaulted. For a positive to
negative output, it must also be programmed to be inverted.

ENABLE LINE FAILURE on WW Modem and STU Interface
This feature is used to monitor for line faults from switched communicators such as Redcare

NOTE: Either of these modules must be plugged into main control module.
Simplified Configurations: Comms (Communications) Configure Group
– Enable Line Failure: Default: No

(UK ACPO = yes)

– Line Fail Polarity: Positive 12VDC going to Negative 0V or Negative 0V going to Positive 12VDC. Default: Positive
Advanced Configurations: S005 03
– Field 2: Parallel STU 8OP Supports Line Fail: (yes)

(no) Default: no

(UK ACPO = yes)

– Field 3: Parallel STU 8OP Line Fail Negative Polarity: (yes)

(no) Default: no = Positive Polarity

Enable Equipment failure point E16 (HSC, Security IP, Trouble). Set delay as 01 immediate in Simplified or Advanced
programming. If the WW Modem or STU Interface have a Line Failure condition, it will be indicated by an HSC fault.

HSC (High Security Communications) is a proprietary communications of CSG Security Inc. and not used in all markets.


Wiring CA38A Alarm Jack for connection to xL Modems

Incoming Phone

Line to CA38A

Alarm Jack

8 Pin Telephone Cord

Telephone Block

Brown

Gray

Red

Green

Red

Green

Black

Yellow

House

Phones

Yellow

Black

CA38A Alarm Jack

Red

Green

Tip

-

Ring

+

House

Phones

Telephone

Line

Seized Ring

Seized Tip

Ring

Tip

Alarm Panel
Digital Phone
Line Connection

Black

Yellow

Red

Green

Green

Red

8 pin phone line cord VEREX part number: 166-4500
The CA38A Alarm Jack is commonly installed by the telephone company and is a requirement for Canadian
installations.
If a supplementary cord and jack are used, they must comply with FCC Part 68.