Wiring, 5v 12v, Keypad command entries – Interlogix Monitor XL Hardware Guide User Manual

Page 9

Advertising
background image

22-0375 rev1.1

Monitor ISM/xL™ Hardware Guide

5

Wiring

1

2

3

4

5

6

7

8

9

0

#

14

3

2

56

(+)5/12VDC

Green LED

Red LED

Data 1 Clock

Ground 0V

Data 0

R
eader

...

5V

12V

Reader

Voltage
Jumper

Red

Ensure power jumper set to 12V

Orange

Controls Door Locked/Unlocked LED

Blue

or

Yellow

Keypad area control communications.

White

Data 1

Green

Data 0

Black

GND + Shield Wire

Arming Station
current rating =
80mA

Maximum cable distance from 2 Dr Access Module to
Arming Station is 500 feet.

Reader Connections at Door Access Module

Arming Station Internal Buzzer follows LCD
Keypad Tones

e.g. Entry/Exit Delay, Work Late Tones etc. as
well as door access conditions e.g. Door Forced.

NOTE:

NOTE: the Keypad area control communications
wire must be connected or the Work Late and
Armed LEDs will flash back and forth. 111-8240
GProxI wire is blue. 111-8270 (switch plate) or
111-8267 (mullion) GProxII wire is yellow.



Keypad Command Entries

<login> represents the form of user identification used e.g. badging card and or ID – PIN entry.

Key Sequence

Command

< login > only

Access (momentary unlock of door)

1 <login>

Turn area off

1 0 <login>

Turn all areas off

2 <login>

Turn area to stay mode

3 <login>

Turn area on

3 0 <login>

Turn all areas on

5 <login>

Toggle between Lock Door and Unlock Door & Disarm area

Door commands or if door is locked and area armed – unlocked and area disarmed.

6 <login>

Work Late in this area by 2 hours at a time from the current time. Scheduled
area only.

This command can only be used again at the end of the first entered 2

hours when the arming station will indicate closing time again with the work late LED
flashing and tones. At that time, this command can be used again to extend the
closing time another 2 hours.

6 n <login>

Work Late in this area for n hours where n = 1…9. Scheduled area only.

7 <login>

Activate armed state LED display for approximately 20 seconds

To determine arming station’s area condition. Armed LED indicates for 20 sec:
green for OFF, red for STAY and flashing red for ON.

9 <login>

Silence alarm (in all areas)

# #

Cancel any keys previously entered

#

If performing a “ ” command with UID/PIN, insert a "#" key between
command and UID/PIN entry (e.g. “ 1 # 341 1234 ” for user 341, pin=1234
trying to arm the area

1).

Advertising