8 zone wiring and mounting – Interlogix Monitor XL Hardware Guide User Manual

Page 14

Advertising
background image

10

Monitor ISM/xL™ Hardware Guide

22-0375 rev1.1

8 Zone Wiring and Mounting

CO

M

I/P

3

I/P

4

I/P

1

I/P

2

I/P

5

I/P

6

I/P

8

I/P

7

CO

M

CO

M

COM

Module Bus

ye

llo

w

g

re

e

n

1 2

1

4

3

2

5

(+

)1

2

V

(

-

)0V

D

a

ta

B

D

a

ta

A

b

la

ck

re

d

1

4

3

2

3

1

3

1

1

3

2

2

2

3

1 2

Inputs

Da

ta

0

Da

ta

1

NO

NC

CO

M

(+

)12V

GND

Outputs

O/P1

Reader

Tamper

Spring

After placing the
keypad on its
base, make sure
the keypad's
securing screw
(supplied) is
always I N !

Apply dealer's logo label
(supplied) in the indented
space on keypad door.

Module Bus
communications
indicator LED

Unit voltage OK
indicator LED

Output 1
enabled LED
Output 2
enabled LED

Current Consumption
= 160mA max.

O/P2

Self resetting 0.5A fuse.

Always secure keypad base to wall using 4 screws.

Recommended mounting height: 1.5
meters (4 feet, 9 inches) from floor
level to the bottom of the keypad.

NOTE: Output 2
current rating is
25mA.

1

2

3

4

5

6

7

8

5 digit serial
number to
program in
Module
Programming

X

XXXX

Each 8 Zone Module 5 digit serial address sticker on the printed circuit board is entered in the “Suite
Security” programming. Not the Module programming.

Output 1 is a form “C” contact that changes state when this output turns on.

Output 2 is a standard output that turns on 12VDC when it is enabled. It has a low current rating of 25mA to
trigger e.g. a low current relay.

Input points can be configured as normally closed or open end of line (with 2.2K resistor) only.

The Master Suite Security User can edit only Suite Security Authority Levels at the Suite Security Keypad and
LCD keypad. All other configurations must be done through the Director Software.

Director Suite Security Authority Level “0”, System Authority Only means the user has no Suite Security abilities.

Suite Security user groups can be allocated in blocks of 8 users. These are Director Suite Security Authority Level
“1”, Suite Security Unassigned. The F + 9 + PIN at a Suite Security keypad requires the user to be predefined in
the Director software database although you do not actually have to assign them to the suite (i.e. Suite Security
Authority of unassigned). A user assigned with suite Security Master Authority or through the Director software by
an Operator can do this via the Suite Security keypad MODULE at a later time. It simply allocates the space in the
database for the possible 8 users per Suite Security keypad similar to how you allocate points for possible future
use. The Director software restricts User's 1-8 to Suite Security keypad MODULE #1, User's 9-16 for Suite
Security keypad MODULE #2, etc.