Module power supply – Interlogix Monitor XL Hardware Guide User Manual

Page 58

Advertising
background image

54

Monitor ISM/xL™ Hardware Guide

22-0375 rev1.1

Module Power Supply

red

Normally Open

Common

Normally Closed

0V

12

TB1

12

TB2

3

12

4

3

12

4

TB5

3

12

TB6

AC Mains
AC Mains

Earth GND
Earth GND

Auxiliary (+)12VDC

0V

Auxiliary (+)12VDC

0V

(+)12V

(

-

) 0V

Data B

Data A

bla

ck

yello

w

gre

en

Module
Bus

(SNAPP)

VBUS

12

TB7

0V

Tamper Input

TB

3

TB4

T

rou

bl

e

Ou

tp

ut

(

-

)

(+)

Battery Connectors

1.

0

AM

P

Out

put

(+)

(

-

)

P8

P7

P6

P5

P4

P9

P10

Manual Battery
Re-start

Battery
reset-able
fuse

Auxiliary power
reset-able fuse

Cover
Tamper
Spring

Module Power

Supply

Anti-Attack Bushing Cap (p/n 364-5102) covers the rear tamper spring. It fits inside an “ O “
Ring Bushing
(p/n 364-5103) that fits inside the metal cabinet’s rear wall, anti-tamper spring,
knock-out. Leave the O ring bushing and cap IN if the rear tamper is not used. If the rear
tamper is used, remove the cap and the O ring with the edge of a flat screw driver. Discard the
O ring. Align the cap to insert in the tamper spring, knock-out hole on the control cabinet back.
Screw the cap by its center hole to the mounting surface. Place the control cabinet over it,
allowing the rear tamper spring to fit inside the cap. The cap will insert in the metal cabinet’s
tamper spring, knock-out hole. Complete securing the metal cabinet to the mounting surface.

Rear Tamper on
back of board.

Momentarily jumper
after a battery has been
connected and there is
no AC mains available.

5 digit serial number
to program in Module
Programming

XXXXX

This unjumpered
connector not used.
Do not jumper.

These unjumpered
connectors not used.
Do not jumper.

Factory set.
Do not adjust.

1 2

SNAPP

Isolate

Battery
Plug

3

12

(+)12V

SNAPP ISOLATE: Jumper/short with wire to enable Module Bus (SNAPP) connector 12VDC.

Battery Cable p/n 166-2645

Not used

P3 jumper in = rear
tamper bypassed

1

1

2

2

Brownout Button: After installation and all power connections are complete, press this button
to establish a frame of reference to detect a brownout.

Button

Wire short
for cover
tamper
spring
operation
only.

AC Mains On
Green LED

Additional Cover

Po

we

r O

n

Gr

ee

n L

E

D

Tro

ubl

e

Ye

llo

w L

E

D

Modu

le

B

u

s

c

o

m

m

u

n

ica

ti

on

s R

e

d

LED

Processor
OK Green
LED
Slow flash.
Fast flash
with no
VBUS
connected.

Ratings:
North American:
Input: 16.5VAC/40VA/50-
60Hz/60W, 50mA
Output: 12VDC
Europe:
Input: 230VAC/50Hz, 50mA
Output: 12VDC
Temp for both: -10°C to
+55°C (14°F to 131°F) @
93%





Refer to Installation Instructions P/N 21-3614 for further information.

Advertising