40 monitor ism/xl™ hardware guide, Power supply, Elevator relay board – Interlogix Monitor XL Hardware Guide User Manual

Page 44: Elevator isolator board, Elevator 2nd elevator, 4 relay boards maximum

Advertising
background image

40

Monitor ISM/xL™ Hardware Guide

22-0375 rev1.1

1 2

1 2

1 2

3

2

1

4

3

2

1

4

3

2

1

12

12

12

3

2

1

3

2

1

4

5

6

3

2

1

4

5

3

2

1

4

5

1

3

2

1

3

2

1

3

2

1

3

2

1

3

2

1

3

2

13

2

13

2

1

1

4

3

2

5

1
2

13
2

3

3 1

3

1

1

3

2

2

2

2

1

3

2

1

3

2

1

3

2

1

3

2

1

3

2

1

3

2

13

2

13

2

1

1

4

3

2

5

1
2

13
2

3

3 1

3

1

1

3

2

2

2

2

1

3

2

1

3

2

1

3

2

1

3

2

1

3

2

1

3

2

13

2

13

2

1

1

4

3

2

5

1
2

13
2

3

3 1

3

1

1

3

2

2

2

2

1

3

2

1

3

2

1

3

2

1

3

2

1

3

2

1

3

2

13

2

13

2

1

1

4

3

2

5

1
2

13
2

3

3 1

3

1

1

3

2

2

2

2

1 2

1 2

1 2

3

2

1

4

3

2

1

4

3

2

1

12

12

12

3

2

1

3

2

1

4

5

6

3

2

1

4

5

3

2

1

4

5

DA

T

A

I

N

DA

T

A

0

DA

T

A

1

)

(+( )

DA

T

A

I

N

DA

T

A

0

DA

T

A

1

)

(+( )

DA

T

A

I

N

DA

T

A

0

DA

T

A

1

)

(+( )

DA

T

A

I

N

DA

T

A

0

DA

T

A

1

)

(+( )

E

lev

1/

2 D

a

ta

0

El

ev

1/

2

D

a

ta

I

n

El

ev

1/

2 D

a

ta

1

GND

)

( +

()

El

ev

1/

2 D

a

ta

I

n

E

lev1

/2 D

a

ta

1

E

le

v

1/

2 D

a

ta

0

AC AC (

-

) (+) (

-

) (+)

12VDC

Battery

16V40VA
TXMR

Power Supply

(P/N 110-5560)

GND

GND

GND

GND

)

(+( )

)

(+( )

Ground Lug

GND

Use all 4 quad
cable wires

WATERPIPE

GROUND

Connect common waterpipe
ground to cabinet GND lug.

DI

N

D0

D1

DI

N

D0

D1

Main Terminal Block

To Relay Boards in Expansion Cabinet

See Notes below.

Interconnect with all expansion
cabinet power supply negatives.

Starter cabinet power supply negative.

To Relay Boards in Expansion Cabinet

Elevator Relay Board

P/N 650-9035

Elevator Relay Board

P/N 650-9035

Elevator Relay Board

P/N 650-9035

Elevator Relay Board

P/N 650-9035

Elevator Isolator Board

P/N 641-9036

Elevator Isolator Board

P/N 641-9036

Cabinet Frame
Tamper Switch
SEE NOTES

)

( +

()

J
5

J
4

J
3

J
2

J
1

J
6

J
7

J
8

J
5

J
4

J
3

J
2

J
1

J
6

J
7

J
8

J
5

J
4

J
3

J
2

J
1

J
6

J
7

J
8

J
5

J
4

J
3

J
2

J
1

J
6

J
7

J
8

ELEVATOR ISOLATOR and RELAY BOARDS in STARTER KIT CABINET

Spare
GND
Lug.
Move as
required.

Spare
GND Lug.
Move as
required.

Shipped as pre-wired for 2 elevator cabs, 16 floors each (when 3 more relay boards and 1 additional
isolator board are added). To change for a single elevator cab, 32 floors maximum (when 3 more
relay boards are added) add jumper wires as shown by dashed lines at Main Terminal Block. See
Packages and Products list, page 10.

Proceed from these connections to more relay boards in add-on Expansion Cabinets.

Always interconnect power supply ground with power supply ground in additional expansion
boxes.

Use pre-wired Main Terminal Block to connect 2 separate isolator board elevator systems.

NOTES:

CABINET FRAME TAMPER SWITCH Each Starter, Expansion cabinet tamper switch must be in
series (normally closed) with the 2 Elevator Module controller tamper connection. Use shielded 4
conductor P/N 120-3401. Connect at tamper terminals on Main Terminal Block. Terminate shield
at ground lug in Elevator Module cabinet. Interconnect shield between additional cabinets but do
not terminate any where else.

1

st

Elevator

2nd Elevator

Address 0

Address 0

Address 1

Address 1

4 Relay Boards
Maximum

(+)

( )

(+) ( )

(+)

( )

( )

(+)

(+)

( )

Power the
Elevator Module
side of the
Elevator Isolator
Boards with a
separate power
supply (P/N 110-
5560).

Advertising