Second elevator connections to 2 elevator module, 2 elevator module, 38 monitor ism/xl™ hardware guide – Interlogix Monitor XL Hardware Guide User Manual

Page 42

Advertising
background image

38

Monitor ISM/xL™ Hardware Guide

22-0375 rev1.1

(+)12V

(

-

)0V

Data B

Data A

14

3

2

1

4

3

2

5

6

1

3

2

1

4

3

2

1

4

3

2

(+)

12V

(

-

)0

V

D

a

ta

A

D

a

ta

B

N.

O

.

Com

.

N.

C.

Com

.

N.

O

.

Co

m

m

on

Co

m

m

on

T

a

m

p

er

Outpu

t

(+

)5

/1

2

V

DC

Gree

n

L

E

D

Re

d L

E

D

Grou

nd 0V

bl

ac

k

ye

llo

w

re

d

g

reen

1

3

2

12

12

2

nd

El

ev D

a

ta

0

N.

O

.

Co

m.

N.

C

.

Co

m

.

N.

O

.

Co

mm

on

By

pas

s

F

ir

e

By

pas

s

C

o

mmo

n

Ta

m

p

e

r O

u

tp

u

t

(+)

5

/12VD

C

Gr

ee

n LED

R

ed

LED

R

e

a

der

1 D

a

ta

1

Gr

oun

d 0V

Rea

der

1

Da

ta

0

P

a

ni

c

I

n

pu

t

1

4

3

2

5 6

1

3

2

1

4

3

2

1

3

2

1 2

1 2

Re

ade

r 2

Da

ta 0

Re

ade

r 2

Da

ta 1

XXXXX

2 Elevator

Module

Self resetting
0.5A fuse.

Low Voltage
LED

Processor OK LED

(normal = slow flash)

Unlock Relay
2 LED

Auxiliary Relay 2 LED

Module Bus communications
indicator LED

Auxiliary
Relay 1 LED

Unlock Relay
1 LED

Reader

Reader

Aux
Rly 2

Aux
Rly 1

Unlock
Rly 1

Unlock
Rly 2

Not Used

Not Used

By

pa

s

s

F

ir

e

By

pas

s

Pan

ic

I

n

put

Module Bus

5V

12V

Reader Voltage

Jumper

5V

12V

Reader Voltage

Jumper

P/N 650-9017

5 digit serial
number to
program in
Module
Programming

red

orange

white

green

black

READER
for
Elevator
Module’s
second
elevator

brown

not used

1

3

2

1

3

2

1 2

1

4

3

2

5

1
2

13
2

RLY1

RLY2

(+)
(

-

)

DATA

DAT

A

DAT

A

0

DAT

A

1

Elevator

Relay Board

Aux
12VDC

(+

)

P

/N

65

0-

90

35

C

u

ta

w

a

y vi

ew

Ea

rth

Co

mm

o

n

Gre

en LED

R

ead

er 1/2 Da

ta

1

R

ead

er

1/2

Da

ta 0

El

ev

1

/2 D

a

ta

0

El

ev1

/2

D

a

ta

In

By

p

a

s

s

Pa

ni

c

In

0V

N

e

g

(

-

)

(+)

12

V

D

C

Gro

und

0V

Co

m

m

o

n

By

pa

s

s

Fir

e

B

y

p

a

ss

Co

m

m

o

n

T

a

m

p

e

r Ou

tput

G

re

en

LED

Re

ade

r 1/

2 D

a

ta

1

Re

ade

r 1/

2 D

a

ta

0

P

ani

c

Ou

t

E

le

v

1/

2 D

a

ta 0

E

le

v

1/

2 D

a

ta 1

El

ev

1/2 Dat

a

I

n

12

VD

C

12

VD

C

Gro

und

0

V

P/

N

641

-9036

12

12

12

3

2

1

4

3

2

1

4

3

2

1

1 2

1 2

1 2

3

2

1

3

2

1

4 5 6

3

2

1

4 5

3

2

1

4 5

(

-

) (+)

(+)

(

-

)

El

ev

1

/2 D

a

ta

1

(

+

)

5 / 1

2

VD

C

Spar

e

Co

mm

o

n

TB1

TB

10

TB4

TB9

TB7

TB3 TB2

TB

13

TB14

TB

1

1

TB12

TB

16

TB

15

0V

Ne

g

0V

N

e

g

Fi

re

B

y

p

a

s

s

Module Bus
connection
from the
motherboard
or paralleling
to another
Module

Power

Supply

(+)

( )

Power

Supply

(+)

( )

Relay and Isolator
board cabinet
12VDC power
supply.

Module Bus

Elevator
Module
12VDC
Power
Supply must
also be
connected to
the Elevator
Module side
of its Isolator
boards.

Elevator
Module

Elevator
side

Elevator
Module
side

Elevator

Isolator

Board

( )

Aux

12

VDC

Reader cable shield. Connect
to control unit ground lug.

Elevator Isolators and Relay boards do not have a 5 digit
serial # to program in Module Programming.

Parallel connections to next Elevator Relay board(s)

Fire Bypass is not intended for
"Life/Safety" applications.

2

nd

El

e

v

D

a

ta

1

1

st

El

ev

D

a

ta

0

1

st

El

ev

D

a

ta 1

2

nd

El

ev

D

a

ta In

1

st

El

ev

D

a

ta

In

ELEVATOR MODULE and ISOLATOR BOARD (2nd elevator connected to 2 Elevator Module)

Reader Voltage
Jumper

5V

1

2

V

Normal

RS485

Second
Elevator
Connections
to 2 Elevator
Module

Reserved for a
Service LCD Keypad
Module

Waterpipe ground input when a
cabinet ground lug is not available.
If quad cable is used, use all four
wires. Terminate two wires in #1
and two wires in #2, for
convenience.

Power to next Elevator Relay board(s) in this cabinet only. NOTE: If more elevator
relay boards are added in additional expansion cabinets with their own power supply -
ALL RELAY BOARD’S POWER SUPPLY NEGATIVES MUST HAVE A COMMON
CONNECTION.

Earth Ground

Gr

oun

d

Elevator Module
current draw =

180mA

.

maximum.

12

Tamper
Switch
Input

RS485 Reader
Connections for
reader runs over 500
ft.

See following

“Wiegand to RS485
Interface Board”

Advertising