Version 2 door module, Do o r 1 do o r 2 – Interlogix Monitor XL Hardware Guide User Manual

Page 37

Advertising
background image

22-0375 rev1.1

Monitor ISM/xL™ Hardware Guide

33

Version 2 Door Module

14

3
2

56

13

2

14

3
2

14

3
2

Module Bus

(+

)1

2

V

(

-

)0

V

D

a

ta

B

D

a

ta

A

(+)12V

(

-

)0V

Data A

Data B

Normally Open

Common

Auxiliary Relay

DO

O

R

1

DO

O

R

2

Normally Closed

Common

Normally Open

Auxiliary Input

Door Unlock Relay

Common

Request to Exit

Door Contact Input

Common

Reader Tamper

Reader Buzzer Negative

5V

12V

Reader

Voltage
Jumper

(+)5/12VDC

Green LED

Red LED

Data 1 Clock

Data 0

Ground 0V

Normally Open

Common

Normally Closed

Common

Normally Open

Common

Request to Exit

Door Contact Input

Common

Reader Tamper

Reader Buzzer Negative

(+)5/12VDC

Green LED

Red LED

Data 1 Clock

Ground 0V

Data 0

Door Unlock Relay

Auxiliary Relay

R
e

a

der

Re

ad

er

Door Control Module
Version 2

Auxiliary Input

This Module Bus is for trunk
connection from the motherboard
or paralleling to another module

This Module Bus is for
connecting a Service
LCD keypad module

ye

llo

w

bl

ac

k

gr

ee

n

re

d

black

yellow

red

green

...

5V

12V

Reader

Voltage
Jumper

Current Rating
= 160mA min. 200mA with all 4 relays and their indicator LEDs energized.

Remember to add reader current. Example readers are 110mA. X 2 = 220mA. Two
readers per each door would be 440mA. This board's total current could be 640mA.

Re

ad

e

r ca

bl

e sh

ie

ld

.

C

o

n

nec

t

t

o

0

V

gr

ou

nd.

Tamper

Pins

13

2

12

12

14

3

2

56

13
2

14

3

2

13
2

12

12

...

Aux Reader Data 0
Aux Reader Data 1

Aux Reader Data 0

Aux Reader Data 1

1

4

3

2

Tamper

Spring

Optional

Tampers

black

green

white

not used

orange

red

white

green

In Reader
Connections

Out Reader
Connections

Module Bus
communications
indicator LED

Door 1
Auxiliary
Relay LED

Door 1

Unlock

Relay

LED

Low Voltage
LED

Processor
OK LED
(normal =
slow flash)

Door 2 Auxiliary
Relay LED

Door 2 Unlock
Relay LED

Self resetting
0.5A fuse.

X

XXX

X

5 digit serial
number to
program in
Module
Programming

Mo

du

le

Bu

s

SPECIAL NOTE:
For Rev A replacement boards this stand off hole must be isolated by the
technician with e.g. a fiber washer on either side of the hole. This is not
required for current Rev D boards and greater. Rev B & C boards do not
exist. The Rev version can be found “silk screened” on the back of the board.


















Refer to Installation Instructions P/N 22-0353 for further information.

Advertising