Smart/Vigil Concentrator to Smart/Vigil Module Inputs and Outputs Conversion Chart

Conc.

Input #

Module

Input #

Conc.

Input #

Input #

Conc.

Output #

Output #

Conc.

Output #

Output #

1

9

C

33

41

1

11

C

41

51

O

2

10

O

34

42

O

2

12

O

42

52

N

3

11

N

35

43

N

3

13

N

43

53

C

4

12

C

36

44

C

4

14

C

44

54

5

13

37

45

5

15

45

55

#

6

14

#

38

46

#

6

16

#

46

56

1

7

15

5

39

47

1

7

17

5

47

57

8

16

40

48

8

18

48

58

9

17

C

41

49

9

9

49

49

O

10

18

O

42

50

10

10

50

50

N

11

19

N

43

51

C

11

21

C

51

61

C

12

20

C

44

52

O

12

22

O

52

62

13

21

45

53

N

13

23

N

53

63

#

14

22

#

46

54

C

14

24

C

54

64

2

15

23

6

47

55

15

25

55

65

16

24

48

56

#

16

26

#

56

66

17

25

C

49

57

2

17

27

6

57

67

O

18

26

O

50

58

18

28

58

68

N

19

27

N

51

59

19

19

59

59

C

20

28

C

52

60

20

20

60

60

21

29

53

61

C

21

31

C

61

71

#

22

30

#

54

62

O

22

32

O

62

72

3

23

31

7

55

63

N

23

33

N

63

73

24

32

56

64

C

24

34

C

64

74

C

25

33

C

57

65

25

35

65

75

O

26

34

O

58

66

#

26

36

#

66

76

N

27

35

N

59

67

3

27

37

7

67

77

C

28

36

C

60

68

28

38

68

78

29

37

61

69

29

29

69

69

#

30

38

#

62

70

30

30

70

70

4

31

39

8

63

71

C

31

41

C

71

81

32

40

64

72

O

32

42

O

72

82

N

33

43

N

73

83

C

34

44

C

74

84

35

45

75

85

#

36

46

#

76

86

4

37

47

8

77

87

38

48

78

88

39

39

79

79

40

40

80

80

C

C

C

C

The first 8 inputs and outputs
of the ISM/AFx are located on
the main control board.

NOTE: This Table applies when the
Smart / Vigil Module is configured
as Module # 1.

Module

Module

Module

Smt/Vig

Smt/Vig

Smt/Vig

Smt/Vig

Smt/Vig

Smt/Vig

Smt/Vig

Smt/Vig

Output Locations on Smart/Vigil Concentrators

Commercial Concentrator: output 9 becomes output 1. Output 10 becomes output 2. Outputs 1 – 8 on the plug on, 8-
zone annunciator card become outputs 3 – 10.
Safe/Vault Concentrator: outputs 1 – 5 start their programming at output 3 – 7.
Safe Seismic Concentrator: output 1 becomes output 3. Output 2 becomes output 4.

Checking Status

When in the Status menu, select App and then SMA for the Smart/Vigil module.

Select SMR to check Smart concentrators. HSC is NOT USED. Printer status and some printer user control is

in the History menu the same as using a Printer module (discussed later in this manual).

Advertising