Chapter 4: Camera setup

28

UltraView IP PTZ 36X Camera User Manual

Parameter

Description

Max bit rate

Specifiy the maximum allowed bit rate. A high image resolution requires that
a high bit rate must also be selected.

Select one of the options: 32 bps, 48, 64, 80, 96, 128, 160, 192, 224, 256,
320, 384, 448, 512, 640, 768, 896, 1024, 1536, 1792, 2048, or Customize
(enter a value manually). Default is 2048.

Frame rate

Specify the frame rate for the selected resolution.

Select one of the options: 1/16, 1/8, 1/4, 1/2, 1, 2, 4, 6, 8, 12, 16, 22, or full
frame (25). Default is full frame (25).

I frame interval

A video compression method. It is strongly recommended not to change the
default value displayed, 25.

RTSP port

Specify the port used to stream video over an RSTP port.

Naming the camera

This is the camera name that is displayed on screen.

To name the camera:

1. In the Remote Configuration folder, click the

Video Setting

subfolder to open

its screen.

2. Enter the camera name in the

Channel name

edit box. The camera name

can have up to 12 alphanumeric characters.

3. Click

Save

to save changes.

Defining a recording schedule

You can define a recording schedule for the camera in the Schedule Recordings
screen under Camera Parameters. The recording is saved on the SDHC card in
the camera. Although all recordings are saved on the DVR, the camera’s SDHC
card provides a backup in case of network failure, for example. See Figure 12 on
page 29.