Ptz channel – Interlogix UltraView IP PTZ 36X Camera User Manual User Manual

Page 42

Advertising
background image

Chapter 5: Motion setup

38

UltraView IP PTZ 36X Camera User Manual

PTZ channel

Use this menu to define the preset, keypad control and auto scan speeds.See
Figure 15 for the screen.

Table 5: PTZ channel menu description

Parameter

Description

Enable proportional pan

This automatically adjusts the pan/tilt speeds in proportion to the
depth of zoom. This function prevents the image on the monitor
from moving too quickly when there is a large depth of zoom.
Default setting is Enable.

When disabled, it can be difficult to manually control the
movement of the camera when zooming in.

Note: This function is enabled by default when setting shadow
tours.

Enable image freeze

When enabled the camera image is frozen while the camera is
moving during a PTZ operation. Default setting is Disable.

Preset speed

Select an option from 1 to 8. Default is 4.

Keypad control speed

Select low, medium or high.

Auto scan speed

Select a value between 1 and 40.

PTZ OSD display

Zoom label

Define for how long the zoom label is displayed on screen. The
label can be displayed for a few seconds, for example, always
displayed (“Always open”) or never displayed (“Always close”).

Select one of the options: 2s, 5s, 10s, always close, always open.
Default is 2s.

PT label

Define for how long the pan/tilt (PT) label is displayed on screen.
The label can be displayed for a few seconds, for example,
always displayed (“Always open”) or never displayed (“Always
close”).

Select one of the options: 2s, 5s, 10s, always close, always open.
Default is 2s

Preset label

Define for how long the preset label is displayed on screen. The
label can be displayed for a few seconds, for example, always
displayed (“Always open”) or never displayed (“Always close”).

Select one of the options: 2s, 5s, 10s, always close, always open.
Default is 2s

Save PTZ power off

Power loss position

When enabled, the camera can return to its previous postion after
a predefined dwell time following a power loss. Select one of the
options: Disable, 30s, 60s, 300s, 600s.Default is 30s.