Chapter 4: Camera setup

34

UltraView IP PTZ 36X Camera User Manual

Parameter

Description

Contrast,
Saturation,
Hue,
Sharpness

the values for each of parameter on the scroll bars.

These values can also be modified in live view

IR cut filter type

This function controls when the dome camera switches to day or night
mode. The dome camera produces high-quality color video during the day
or when light levels are high. At night or when light levels are low the
camera switches to monochrome and removes the infrared filter to improve
IR sensitivity. There are three options:

Auto: The camera automatically switches between day and Night mode
depending on the light levels. This is the default setting.

Day: Manually select Day mode.

Night: Manually select Night mode.

IR cut filter level

This is the light level at which the IR cut filter in the camera switches to day
or night mode. The options include Low, Mid, and High. Default is Mid.

Low indicates a higher sensitivity and can improve reliability of the lens so
that it is fast to switch to Day mode and relatively difficult to change into
Night mode; High indicates that it is fast to switch to Night mode and difficult
to change into Day mode.

Note: This option depends on the camera model.

Focus style

Select one of the three options to control camera focus:

Auto focus: The lens continuously adjusts to the correct focus automatically
for the sharpest picture. This is the default setting.

Manual: The focus is adjusted manually by clicking the Focus buttons on
the Web browser..

Semiautomatic: The focus is fixed when the camera is not moving or
zooming. When PTZ is activated, the focus is automatically adjusted.

Focus limited

Defines the shortest distance for auto focus.

Set it to 1 cm, 30 cm, 1 m or 3 m.

Advanced configuration parameters:

Exposure

Specify the method the camera uses to adjust to different light levels:

Auto: Iris, shutter speed and gain/manual automatically adjust to get a
consistent video output level. Default value.

Iris first: The iris controls exposure. Shutter speed and gain/manual
function are disabled.

Shutter first: The shutter speed controls exposure. Iris and gain/manual
functions are disabled.

Manual: Shutter speed and iris are manually controlled.

Shutter

Specify the shutter speed. Select one of the speeds available:

1/1, 1/2 , 1/3, 1/6, 1/12/, 1/50 (1/60), 1/123, 1/150, 1/215, 1/425, 1/1000,
1/1750, 1/3500, or 1/10000

Iris

The iris opens and closes in response to changing lighting conditions.

Set the response level of the iris to f1.4, f1.6, f2.0, f2.4, f3.4, f4.0, f4.8, f5.6,
f6.8, f8.0, f9.6, f11, f14, f16, f19, or f22

Zoom limit

Define a limit to the telephoto zoom. Telephoto zoom is the camera’s optical
zoom multiplied by digital zoom. When the zoom limit is set to the minimum
value, the digital zoom is disabled and the optical zoom is at maximum
value.