Specifications, System requirements, Cable requirements – Interlogix UltraView IP PTZ 36X Camera User Manual User Manual

Page 9

Advertising
background image

Chapter 2: Installation

UltraView IP PTZ 36X Camera User Manual

5

Figure 2: Overview of the dome camera

1. Ethernet RJ-45 connector.

Connect to the network devices.

2. Video output.

Connect the BNC connector to a CCTV
monitor. Optional.

3. Power supply cord.

Connect +24 VAC power supply.

4. Housing.

5. PTZ module.

6. Bubble.

Specifications

Operating temperature

Pendant housing: -10 to +50 °C (-14 to +122 °F)

Flush housing: -30 to +65 °C (-22 to +149 °F)

Power supply

24 VAC +/- 4 VAC

Power consumption

30 W (heater on), 15 W (heater off)

Dimensions (mm)

Pendant housing: Ш 220 Ч 261 mm (Ш 8.66 Ч10.27 in.)
Flush housing: Ш 206 Ч 241 mm (Ш 8.11 Ч 9.49 in.)

Environmental

Pendant housing: IP66
Flush housing: IP54

Weight

5 kg (11 lb.)

System requirements

For proper operation, adhere to the following operational, cable, and power
requirements for the dome camera.

Cable requirements

Table 1 on page 6 lists the requirements for the cables that connect to the dome
camera.