4 mechanical switch interface, 1 original or home signal, 2 end-limit switch signal – ADLINK PCI-8144 User Manual

Page 56: 3 slow down switch, Mechanical switch interface

Advertising
background image

46

Operation Theory

4.4

Mechanical switch interface

We provide some dedicated input pins for mechanical switches
like original switch (ORG), plus and minus end-limit switch (

±

EL),

slow down switch (SD). These switches’ response time is very
fast, only a few ASIC clock times. There is no real-time problem
when using these signals. All functions are done by motion ASIC.
The software can just do nothing and only need to wait the results.

4.4.1

Original or home signal

Our controller provides one original or home signal for each axis.
This signal is used for defining zero position of this axis. The logic
of this signal must be set properly before doing home procedure.
Please refer to home mode section for details.

4.4.2

End-Limit switch signal

The end-limit switches are usually installed on both ending sides
of one axis. We must install plus EL at the positive position of the
axis and minus EL at the negative position of the axis. These two
signals are for safty reason. If they are installed reversely, the pro-
tection will be invalid. Once the motor’s moving part touches one
of the end-limit signals, the motion controller will stop sending
pulses and output an ERC signal. It can prevent machine crash
when miss operation.

4.4.3

Slow down switch

The slow down signals are used to force the command pulse to
decelerate to the starting velocity when it is active. This signal is
used to protect a mechanical moving part under high speed move-
ment toward the mechanism’s limit. The SD signal is effective for
both plus and minus directions.

Advertising