ADLINK PCI-8144 User Manual

Page 71

Advertising
background image

MotionCreatorPro

61

In “Cont. Move,” both the value and sing is effective. –
5000.0 means 5000.0 in the minus direction.

Z

Accel. Time: Set the acceleration time in units of sec-
ond. Tdec is the same as tacc.

Z

Move Delay: This setting is effective only when repeat
mode is set “On.” It will cause the 8144 to delay for a
specified time before it continues to the next motion.

14.Play Key:

X

Left play button: Clicking this button will cause the 8144
start to outlet pulses according to previous setting.

Z

In “Relative Mode,” it causes the axis to move forward.

Z

In “Cont. Move,” it causes the axis to start to move
according to the velocity setting.

X

Right play button: Clicking this button will cause the 8144
start to outlet pulses according to previous setting.

Z

In “Relative Mode,” it causes the axis to move back-
wards.

Z

In “Cont. Move,” it causes the axis to start to move
according to the velocity setting, but in the opposite
direction.

15.Stop Button: Clicking this button will cause the 8144 to

stop. The related function is _8144_emg_stop().

16.I/O Status: The status of motion I/O. Light-On means

Active, while Light-Off indicates inactive. The related
function is _8144_get_mio_status().

17.Motion Status: The status of motion when running.

Light-On means Active, while Light-Off indicates inac-
tive. The related function is
_8144_motion_status()

.

Advertising