Multi-Appliance Comfort Control

Ducted Gas Heating

USING YOUR COMFORT CONTROL

There is 2 ways to operate your Comfort Control. You can use MANUAL and select the operation modes
or you can use the AUTO and program the operation modes to happen automatically.

M

ANUAL

O

PERATION

1. Turn the comfort control on, press and release the ON/OFF

button. If there is only a central heater fitted the control will default
to Heat Cool.
NOTE: Your Comfort Controller is designed to automatically
detect the appliances you have installed, once coded. Controller
options not required for your appliances will usually not be visible
on your Comfort Control display. So don't worry if you don't see all
the menu items listed in this book.

2. Press the MANUAL/AUTO button until Manual is displayed.

3. Press the HEAT/COOL/FRESH AIR button until Heat appears at

the top of the display.

4. Press & hold the ▼ or ▲ buttons to decrease or increase SET

TEMP or, press & release buttons to change the SET TEMP one
degree at a time.

5. The Comfort Control measures the room temperature using a

thermostat inside its case. When the room temperature is colder
than the SET TEMP the Heater will come on after a 30 seconds
ignition process.

6. The Comfort Control will run both the modulating and non

modulating heaters until it measures temperature a little above
your SET TEMP. The thermostat will then turn off the heater until
the temperature falls a little below set temperature before
restarting.

7. For modulating heaters, the operation of the heater is as follows:

• If at start up the room temperature is more than 2.0° below

the set temperature, the central heater will start up at high
fan speed and high gas rate quickly bringing your house up
to temperature.

• As the room temperature gets closer to the set temperature

the central heater will reduce the room air fan and the gas
rate to the burner.

• When the thermostat reaches the set temperature the central

heater will be on low fan and the gas will modulate to low
fire.