Comfort control, Manual operation – Bonaire Comfort Control - RF/LV User Manual

Page 25

Advertising
background image

Multi-Appliance Comfort Control

Dual Cycle Addon Refrigerated Air Conditioning

COMFORT CONTROL

Using your Comfort Control for manual operation of your Add-on Refrigerated Air Conditioner is the same
as your gas central heater where you want direct control, without timers or programming.

Note: When the Add-on cooler is selected, the default setup for the room air fan is to
thermostatically cycle with the condenser unit until the control is turned OFF or the control is
programmed OFF.

M

ANUAL

O

PERATION

1. To turn the comfort control ON, press and release the

ON/OFF button. The controls will display HEAT and or COOL.

2. Press the MANUAL/AUTO button until Manual is displayed.

3. Press the HEAT/COOL/FRESH AIR button until COOL

appears at the top of the display. The heater fan will start
immediately.

4. Press & hold the ▼ or ▲ buttons to decrease or increase

Set Temp or, press & release buttons to change the Set
Temp
one degree at a time.

5. The Comfort Control measures the room temperature using a

thermostat inside its case. When the room temperature is
warmer than the Set Temp the add-on cooler condenser will
cycle on.

6. The Comfort Control will run the Add-on Cooler until it

measures temperature a little below your Set Temp and turn
off the add-on cooler condenser.

7. The operation of the Add-on cooler is as follows:

• The Add-on cooler will start almost immediately when first turned ON. Once the unit has turned

OFF when in operation there is a 5 - 8 minute delay before it will resume again and a minimum
of 5 minutes operating timer before it can turn off again.

• When the room temperature has gone below the set temperature by approximately a ½º the

add-on cooler condenser will cycle off. The room air fan will also cycle off.

• When the temperature has increased to approximately 1º above set temperature the add-on

cooler condenser and room air fan will restart.

• As your activities vary, you may find you need different temperature settings, e.g. a temperature

comfortable for sitting is usually too cold compared to when you’re moving about.

• For economical operation, set a low SET TEMP during the day when you are active. Switch the

Comfort Control OFF when asleep and ON again when awake. These cost saving functions can
be programmed to operate automatically (see Programmed Control).