Controls- Installation / Setup / Commissioning

SETTING UP THE CONTROLS – DUAL CYCLE REFRIGERATIVE AIR CONDITIONING

The PNE control board in the Bonaire Central Heating units, has the option to run the room air fan in
continuous mode or cycling OFF / ON with the dual cycle refrigerative condenser unit.

S

ETTING THE

F

AN

C

ONTROL FROM

A

UTO TO

C

ONTINUOUS

M

ODE

S

ETTING

P

ROCEDURE

To alter the fan operation mode, you will need to change the screen display to reflect evaporative air
conditioning COOL FRESH AIR for a short period of time.
Step 1

Using the HEAT / COOL / FRESH AIR button set the unit operation to COOL (for dual cycle
refrigerative air conditioning) only.

Step 2

Press and hold down the HEAT / COOL / FRESH AIR and the ECONOMY / BOOST
BUTTONS for approximately 5 seconds and the screen display will change to COOL FRESH
AIR.

Step 3

Setting the fan cycle mode

1. Make sure the controller is in MANUAL

mode

and is set to COOL FRESH AIR.

2. Press the ENTER button and the MANUAL / AUTO

buttons together for 10 seconds pressing the
ENTER button first. The word OPT and some
numbers will flash on the screen.

3. Using the ▼ or ▲buttons make the top number

read 02. Press ENTER.

4. Using the ▼ or ▲ buttons change the number of

the second line to 01. Press ENTER.

The central heater fan is now set to “continuous operation” for the dual cycle refrigerative air
conditioning.

Step 4

Turn the controller OFF then ON again to transmit the new information to the heater control
board.

Step 5

Finally, you will need to change the screen back to COOL for dual cycle refrigerated air
conditioner mode. Ensure the screen displays COOL FRESH AIR.
Press and hold down the HEAT / COOL / FRESH AIR and the ECONOMY / BOOST
BUTTONS for approximately 5 seconds and the screen display will change to COOL.

The central heater fan is now set to “continuous operation” for the dual cycle refrigerative air conditioning.
The room air fan will now run continuously and the condenser will cycle on and off.

As the add-on cooler is an add-on to your ducted gas central heater there are no further setup functions to
be completed.