Controls- Installation / Setup / Commissioning

SETTING UP THE CONTROLS – DUCTED EVAPORATIVE AIR CONDITIONING
S

ETTING

M

INIMUM

F

AN

S

PEED

1. Using the MANUAL/AUTO button set the unit to MANUAL

2. Using the HEAT/COOL/FRESH AIR button set the unit to

COOL FRESH AIR

3. Adjust the fan speed to the minimum fan speed level and

press ENTER.

4. Press the ENTER and ECONOMY/ BOOST buttons together

for approximately 10 seconds pressing the ENTER button first.

5. The words FAN SPEED and a number under the room

temperature will flash.

6. Adjust minimum fan speed to a number suitable to the system

design. Ensure that the motor does not over-temp if setting the
fan speed lower.

7. Press ENTER to keep new fan speed.

S

ETTING

M

AXIMUM

F

AN

S

PEED

Maximum fan speed can only be access after the minimum fan
speed has been checked.

1. Using the MANUAL/AUTO button set the unit to MANUAL.

2. Using the HEAT/COOL/FRESH AIR button set the unit to

COOL FRESH AIR.

3. Using the ECONOMY/BOOST button set the unit to BOOST.

Press ENTER.

4. Press the ENTER and ECONOMY/ BOOST buttons together

for approximately 10 seconds pressing the ENTER button first.

5. The words FAN SPEED and a number under the room

temperature will flash.

6. Adjust maximum fan speed to 35 or a number to suit the

system design.

7. Press ENTER to keep new fan speed.

Setting the fan speeds to a low setting should be completed by an
authorised installer / service technician. Motor warranty may be
voided for incorrect settings.