Boost, Timer mode – Bonaire Comfort Control - RF/LV User Manual

Page 32

Advertising
background image

Multi-Appliance Comfort Control

Ducted Evaporative Air Conditioning

BOOST

BOOST operates the Fresh Air Conditioner at its highest fan speed. This function can be used to give a
quick over ride to your normal operating settings.

BOOST is used only in MANUAL mode.

Press the ECONOMY/BOOST button. All the bars are
displayed for full fan speed.

Press the ECONOMY/BOOST button again and the unit will resume its
previous manual settings.

TIMER

MODE

Using your Comfort Control for timer controlled operation of your ducted evaporative air conditioner when
you want the unit to turn ON or OFF at a specific time at predetermined settings. The timer modes are
only able to be set for any one day at a time.

1. START TIME – Before setting the start time

Press MANUAL/AUTO button for MANUAL or THERMOSTAT
mode.

For MANUAL mode select COOL FRESH AIR or FRESH AIR
only and set the FAN SPEED.

For THERMOSTAT mode adjust the thermostat setting as
required

Press the SET TIME/PROGRAM button until START TIME
flashes on the screen.

Set the timer by using the ▼ or ▲ buttons. Hold the button
down until the correct hours and minutes appear.

The unit will now start at the time set using the last mode
setting used on the controls.

2. STOP TIME –

Press the SET TIME/PROGRAM button until STOP TIME
flashes on the screen.

Set the timer by using the ▼ or ▲ buttons. Hold the button
down until the correct hours and minutes appear.

The unit will now start at the time set using the last mode
setting used on the controls.