Water management – Bonaire Comfort Control - RF/LV User Manual

Page 29

Advertising
background image

Multi-Appliance Comfort Control

Ducted Evaporative Air Conditioning

W

ATER

M

ANAGEMENT

All evaporative air conditioners need some water to go

to waste to prevent build-up of mineral deposits in the

system. Your unit has been supplied with a dump

valve as well as a bleed control to provide maximum

options for best water management.

The correct setting of the dump valve and bleed will

ultimately govern the life of the unit. Should there be

evidence of a build up of mineral deposits in the unit,

review the dump and or bleed-off values.

Failure to manage the correct levels of dissolved solids

in the unit will void warranty. Refer to your local dealer

for best settings.

Dump Valve

The dump valve provided with your unit is able to be

operated with various timed dumping options (0, 1, 2,

4, 8, 12, 24 hours).

Dumping cycles will have to be activated (refer to the

setup section of this document) and set in accordance

with the water quality in your area. In areas of good

water quality, the correct dumping cycle only may

suffice and the bleed-off function in the Dialflo may not

be required. Increased water hardness may require a

bleed rate as well as a dump cycle and increased

maintenance.

Drainage from the dump valve must be plumbed

away in accordance with local and state plumbing

requirements. However this water could also be

stored in a non drinking water tank for other use.

Set the Water Distribution Flow Rate

To set the water distribution rate locate the DIALFLO

externally on one of the unit corner posts. Rotate the

filter knob (the outer knob) anti-clockwise for more

water and clockwise for less water. Do this before

setting a bleed rate.

Set the BLEED-OFF Rate.

Use the DIALFLO to rotate the BLEED knob (the

inner knob) clockwise for more water flow and anti

clockwise for less.

Note: Hold the distribution knob (Filters) while setting

the bleed rate as the distribution flow rate may go out

of adjustment.

Comfort Control - PNE

Page 29