SETTING UP THE CONTROLS – DUCTED GAS CENTRAL HEATING
S

ETTING

M

INIMUM

F

AN

S

PEED

1. Using the MANUAL/AUTO button set the unit to MANUAL.

2. Using the ECONOMY/BOOST button set the unit to

ECONOMY.

3. Press the ENTER and ECONOMY/ BOOST buttons for

approximately 10 seconds pressing the ENTER button first.

4. The words FAN SPEED and a number under the room

temperature will flash.

5. Adjust minimum fan speed to 27 or a number suitable that the

heater does not go out on over-temperature.

Press ENTER to keep new fan speed.

S

ETTING

M

AXIMUM

F

AN

S

PEED

1. Using the MANUAL/AUTO button set the unit to MANUAL

2. Using the ECONOMY/BOOST button set the unit to BOOST

3. Press the ENTER and ECONOMY/ BOOST buttons for

approximately 10 seconds pressing the ENTER button first.

4. The words FAN SPEED and a number between the 2 bars will

flash.

5. Adjust maximum fan speed to 35 or a number suitable that the

unit does not go out on over-temperature.

Press ENTER to keep new fan speed.

Setting the fan speeds to a low setting should be completed by an authorised installer / service technician.
Motor warranty may be voided for incorrect settings.

S

ETTING

T

HE

Z

ONE

A

VAILABILITY

The unit default is for all zones to be available. To filter out the zones not being used:

1. Press the ENTER and CLEAN FILTER/ZONE ABCD buttons for 10 seconds pressing the ENTER

button first.

2. Using the ▼ or ▲buttons select the zone combination required AB, ABC or ABCD.

3. Press ENTER to keep the combination.

Now only the zone combination selected will be available for use when operating the zone requirements.