Setting procedure, Setting minimum fan speed, Setting maximum fan speed – Bonaire Comfort Control - RF/LV User Manual

Page 42: Setting the zone availability filter

Advertising
background image

Multi-Appliance Comfort Control

Controls- Installation / Setup / Commissioning

S

ETTING THE

F

AN

C

ONTROL FROM

C

ONTINUOUS TO

A

UTO

M

ODE

S

ETTING

P

ROCEDURE

The comfort control should be in the COOL (for Refrigerative air conditioning) and the manual mode.
To alter the fan operation mode, you will need to change the screen display to reflect evaporative air
conditioning COOL FRESH AIR for a short period of time.
Step 1

Using the HEAT / COOL / FRESH AIR button set the unit operation to COOL (for dual cycle
refrigerative air conditioning) only. Press Enter.

Step 2

Press and hold down the HEAT / COOL / FRESH AIR and the ECONOMY / BOOST
BUTTONS for approximately 5 seconds and the screen display will change to COOL FRESH
AIR.

Step 3

Set the fan cycle mode

1. Make sure the controller is in MANUAL mode

and is set to COOL FRESH AIR.

2. Press the ENTER button and the MANUAL /

AUTO buttons together for 10 seconds pressing
the ENTER button first. The word OPT and some
numbers will flash on the screen.

3. Using the ▼ or ▲ buttons make the top number

read 02. Press ENTER.

4. Using the ▼ or ▲buttons change the number of

the second line to 00. Press ENTER.

Step 4

Turning the controller OFF then ON will transmit the new information to the heater control
board.

Step 5

Finally, you will need to change the screen back to COOL for dual cycle refrigerated air
conditioner mode. Ensure the screen displays COOL FRESH AIR.
Press and hold down the HEAT / COOL / FRESH AIR and the ECONOMY / BOOST
BUTTONS for approximately 5 seconds and the screen display will change to COOL.

The central heater fan is now set to “auto operation” for the dual cycle refrigerative air conditioning. The
room air fan will now cycle on and off with the dual cycle refrigerative condensing unit. Please note there
will be time delays with the on and off cycling of the refrigerative condensing unit.

S

ETTING

M

INIMUM

F

AN

S

PEED

The add-on cooling only has one speed of operation.

S

ETTING

M

AXIMUM

F

AN

S

PEED

There is no maximum speed adjustment as the add-on cooler default is maximum speed.

S

ETTING

T

HE

Z

ONE

A

VAILABILITY

F

ILTER

This will be the same setup as already available for Ducted Gas Central Heating.

Comfort Control - PNE

Page 42