Multi-Appliance Comfort Control

Controls- Installation / Setup / Commissioning

C

ODING

T

HE

U

NIT

There is a 4 minute window from the timer the 240V has been turned on to the control board in which to
code the unit.

1. Turn the 240V power ON to the unit. If the power has already been applied, turn the power OFF, then

ON again.

2. Press the V arrow and the ON/OFF button for 5 seconds until the word “CODE” flashes.

3. Code flashes for 15 seconds. When code stops flashing the unit is now ready to turn on.

C

HECKING

T

HE

S

IGNAL

RF

R

EMOTE

C

ONTROL

O

NLY

.

There are 3 ways you can check if the wall control is communicating
with unit control board.

1. The green light on the unit control board will flicker when

receiving a signal.

2. The transmission symbol on the control will show for a flash

only. If it hangs for approximately 2 seconds there is no
transmission.

3. Press the MANUAL/AUTO and CLEAN FILTER/ZONE ABCD

for 15 seconds.

If the 2 dots between the hours and the minutes flash
together signal OK. If the 2 dots alternate there is no
communication.

Press ENTER in each location to check the signal.

The test function stays active for 5 minutes after the
last time ENTER is pressed. Where there is no signal,
re-coding the unit.

C

HANGING THE

C

ODE

It is possible for the Code (digital address) to be duplicated in another installation nearby which will
interfere with the successful operation of your unit. To change the code:

1. Turn the electricity to the unit OFF, then ON.

2. Press the HEAT/COOL/FRESH AIR button and the ON/OFF button for 5 seconds until the words

SET CODE and 4 digits show.

3. Each digit can be altered using the ▼ or ▲ buttons. Press ENTER after each digit or digit change.

When all digits have been changed the word CODE will appear briefly until the update has taken
place.

There is a 4 minute window in which to code the unit. Code flashes for 15 seconds. When code stops
flashing the unit is now ready to turn on.