Xtramus NuStreams-P6GW V1.0 User Manual

Page 43

Advertising
background image


Connection Setting

et

input the static IP address you set in

the DUT here.

WAN Link Type: Choose the WAN connection type for
DUT testing. Three WAN Link Types are available:
DHCP, Static IP, and PPPoE. The WAN Link Type s
here must be the same with the setting of the DUT.

DUT WAN Static IP: If the WAN Link Type is set as
Static IP, please

ttempting to establish connection

put the gateway IP address you set

Connection Wait Timeout: This function sets the
duration of time for a
with DHCP server.

WAN Gateway IP: If the WAN Link Type is set as
Static IP, please in
in the DUT here.

Ts’

match DUT vender’s

CP Process if Valid: Disable or enable DHCP

server.

Check Vender ID: Enable this function to check DU
MAC address and see if they
designated MAC address.

Skip DH

If Check Vender ID is enabled, please input the vender’s designated MAC address here for

Vendor MAC:
comparisons.

VLAN Setting

LAN VLAN Tag: Add VLAN tags to all LAN packets.

LAN VLAN ID: VLAN ID for LAN.

WAN VLAN Tag: Add VLAN tags to all WAN packets

WAN VLAN ID: VLAN ID for WAN.

Test Traffic

Packet Length: Length of testing packets.

ount of time

Delay Time After Learning: When enabled,
NuStreams-P6GW will halt for the set am
after performing network learning.

Test Time: The duration of time for DUT test.

Delay Before Report: When enabled,
NuStreams-P6GW will halt for the set amount of time
before report.

Test Delay: When enabled, NuStreams-P6GW will h
for the set amount of time before starting DUT test.

alt

WAN to LAN Utilization (%): The traffic flow ratio from
WAN to LAN, presented in percentage (1~100).

Flow Control: W
transmitting rate w

hen Flow Control is enabled, the

ill drop if traffic overflow occurs.

o from

LAN to WAN Utilization (%): The traffic flow rati
LAN to WAN, presented in percentage (1~100).

Pass/Fail Criteria

Loss Tolerance (pkts): The acceptable number of lost

n data transmitting during tests (0~9999).

rance (pkts): The acceptable number of

exc

packets in data transmitting during tests

packets i

Excess Tole

ess

(0~9999).

Apply Run

• Click this button to apply all the settings you’ve made and save the settings to NuStreams-P6GW.

* Note: It is recommended to perform WLAN tests in a shielding room.

Note: When WLAN is enabled, NuStreams-P6GW will attempt to connect with the first WAP

(Wireless Access Point) that appears in it

*

s SSID list. If that WAP is encrypted, NuStreams-P6GW

will apply the password you input here.

43

E-mail: [email protected]

Website: www.Xtramus.com

XTRAMUS TECHNOLOGIES

®

Advertising
This manual is related to the following products: