Thermal Validation

MVME55006E Single Board Computer Installation and Use (6806800A37J)

122

The preferred measurement location for a component may be junction, case, or air as specified
in the table. Junction temperature refers to the temperature measured by an on-chip thermal
device. Case temperature refers to the temperature at the top, center surface of the
component. Air temperature refers to the ambient temperature near the component.

Table B-1 Thermally Significant Components

Reference

Designator

Generic Description

Max. Allowable

Component

Temperature (deg.

C)

Measurement

Location

U2, U3

Flash, soldered

85

Ambient

U16

Gigabit Ethernet

119

Case

U22

System controller

110

Case

U24

MPC7457 processor

103

Case

U25

VME-to-PCI bridge

70

Ambient

U27

Clock buffer

95

Case

U31

PCI bridge

70

Ambient

U41-43, U45-
47, U54-56,
U60-62, U64-
66, U67-69

SDRAM

85

Case

U123-124

L3 Cache

115

Case