Hardware Preparation and Installation

MVME55006E Single Board Computer Installation and Use (6806800A37J)

27

1.7.2.1

Ethernet

Four 3-pin planar headers (J6, J7, J100, J101) and four 2-pin planar headers (J34, J97, J98, J99)
are for 10/100/BaseT Ethernet 2 selection.

Ethernet 1 is the Gigabit Ethernet port and is front panel only.

For J6, J100, J7 and J101, install jumpers across pins 2-3 on all four headers for rear P2 Ethernet.
For front-panel Ethernet, install jumpers across pins 1-2 on all four headers.

For J34, J97, J98 and J99, no jumpers are installed for front-panel Ethernet. For rear P2 Ethernet,
install jumpers across pins 1-2 on all four headers when in SBC/IPMC761 mode.

1.7.2.2

PMC/SBC Mode Selection

The MVME5500 is set at the factory for PMC mode. The SBC/IPMC761 mode should only be
selected when using the IPMC761 module in conjunction with the MVME761 transition
module. The PMC mode should be selected when using PMC modules with specific user I/O in
conjunction with the corresponding transition module. PMC mode should also be selected
when using PrPMC modules.

If the rear P2 Ethernet is selected by jumpers J6, J7, J100, and J101, the Ethernet signals also
connect to PMC 1 user I/O connector J14. If a PMC card is plugged into PMC slot 1, there may be
a conflict between the I/O from the PMC card and the rear Ethernet signals. This conflict does not
occur with the IPMC761 or IPMC712 modules.