MOTLoad Firmware

MVME55006E Single Board Computer Installation and Use (6806800A37J)

79

VMEbus A32/D32 addresses from 0x00000000 to (local DRAM size) address the

local memory of the MVME5500.

The following sections provide additional information pertaining to the VME firmware settings
of the MVME5500. A few VME settings are controlled by hardware jumpers while the majority
of the VME settings are managed by the firmware command utility vmeCfg.

4.5.1.1

CR/CSR Settings

The firmware supports both Auto Slot ID and Geographical Addressing for assigning the
CR/CSR base address dependent on a hardware jumper setting. See the VME64 Specification
and the VME64 Extensions for details. As a result, a 512K byte CR/CSR area can be accessed
from the VMEbus using the CR/CSR AM code.

4.5.1.2

Displaying VME Settings

To display the changeable VME setting, type the following at the firmware prompt:

vmeCfg -s -m
Displays Master Enable state

vmeCfg -s -i(0 - 7)
Displays selected Inbound Window state

vmeCfg -s -o(0 - 7)
Displays selected Outbound Window state

vmeCfg -s -r184
Displays PCI Miscellaneous Register state

vmeCfg -s -r188
Displays Special PCI Target Image Register state

vmeCfg -s -r400
Displays Master Control Register state

vmeCfg -s -r404
Displays Miscellaneous Control Register state

vmeCfg -s -r40C
Displays User AM Codes Register state

vmeCfg -s -rF70
Displays VMEbus Register Access Image Control Register state