3 editing vme settings, 4 deleting vme settings, Motload firmware – Artesyn MVME55006E Single Board Computer Installation and Use (July 2014) User Manual
Page 80

MOTLoad Firmware
MVME55006E Single Board Computer Installation and Use (6806800A37J)
80
4.5.1.3
Editing VME Settings
To edit the changeable VME setting, type the following at the firmware prompt:
vmeCfg -e -m
Edits Master Enable state
vmeCfg -e -i(0 - 7)
Edits selected Inbound Window state
vmeCfg -e -o(0 - 7)
Edits selected Outbound Window state
vmeCfg -e -r184
Edits PCI Miscellaneous Register state
vmeCfg -e -r188
Edits Special PCI Target Image Register state
vmeCfg -e -r400
Edits Master Control Register state
vmeCfg -e -r404
Edits Miscellaneous Control Register state
vmeCfg -e -r40C
Edits User AM Codes Register state
vmeCfg -e -rF70
Edits VMEbus Register Access Image Control Register state
4.5.1.4
Deleting VME Settings
To delete the changeable VME setting (restore default value), type the following at the
firmware prompt:
vmeCfg -d -m
Deletes Master Enable state
vmeCfg -d -i(0 - 7)
Deletes selected Inbound Window state
vmeCfg -d -o(0 - 7)
Deletes selected Outbound Window state
vmeCfg -d -r184