3 flash boot bank select header (j8), Figure 1-4, J28 and j32 settings – Artesyn MVME55006E Single Board Computer Installation and Use (July 2014) User Manual
Page 30: Figure 1-5, J102 - j110 settings, Figure 1-6, J8 settings, Hardware preparation and installation
Hardware Preparation and Installation
MVME55006E Single Board Computer Installation and Use (6806800A37J)
30
1.7.3
Flash Boot Bank Select Header (J8)
A 3-pin planar header selects the boot Flash bank. No jumper or a jumper installed across pins
1-2 selects Flash 0 as the boot bank. A jumper installed across pins 2-3 selects Flash 1 as the
boot bank.
Figure 1-4
J28 and J32 Settings
Figure 1-5
J102 - J110 Settings
J28
J32
J28
J32
3 2 1
3 2 1
3 2 1
3 2 1
PMC Mode
SBC/IPMC712 Mode
(factory configuration)
J28
J32
3 2 1
3 2 1
SBC/IPMC761 Mode
J102 –
3 2 1
P2 PMC 2 I/O
J110
J102 –
3 2 1
P2 IPMC I/O
J110
(factory configuration)
(extended SCSI)
Figure 1-6
J8 Settings
J8
1
2
3
1
2
3
Boots from Flash device 0
J8
J8
1
2
3
(factory configuration)
Boots from Flash device 0
Boots from Flash device 0
Boots from Flash device 1