12

2

E

QUIPMENT

DESCRIPTION

2.1 O

VERVIEW

ALS

380

2.1.3

Technical data

Characteristic values

Labels

1) Longer labels are possible when product distance is increased accordingly

Ambient conditions

Dimensions

Casing

Electrical system

1) Customer options

Control system

Emissions

Dispensing speed
ALS 380:
ALS 380 HS:

0.5 m/min to 80 m/min
0.5 m/min to 100 m/min

Stop accuracy (at the
dispensing edge):

± 0.5 mm

Rewind unit:

Spreader mechanism

Label sensor:

Manual or automatic set-
ting

Operation:

programmable, can be set
via the operator panel,
The settings can be stored
in 11 data banks

Speed control:

Automatic dispensing
speed, with RPM-
transmitter

Label width
(incl. backing material): max. 155 mm

Label length at
maximum dispensing
speed:

min. 16 mm
max. 250 mm

1)

Label roll

Outer diameter
Core diameter:

max. 400 mm
76.2 mm

Distance from dispens-
ing edge to label sen-
sor:

min. 20 mm

Temperature

Operation:
Storage:

5°C to 40°C
5°C to 70°C

Relative humidity:

30 % to 80 %,
not condensing

Dimensions

Width:
Height:
Depth:

735 mm
795 mm
400 mm

Weight
ALS 380:
ALS 380 HS:

50 kg
55 kg

Covering for the control-
electronics:

Polyurethane (PUR),
10 mm thick

Front plate:

Aluminium, anodized,
15 mm thick

Power consumption:

500 VA

Mains connection

Nominal voltage:

Frequency:

110 V / 120 V / 130 V /
200 V / 220 V / 230 V/
240 V

1)

50 Hz / 60 Hz

1)

Type of protection

IP41 (protected against
vertically falling drops of
water, not protected
against sprayed water)

Drive system:

2 stepping motors,
1 AC motor

Control electronics:

Integrated

Options:

V24 interface
Frequency inverter for
motor control

Sound pressure level at
a distance of 1 m:

75 db (A)

Advertising