3 dispensing speed (velo), Automatic dispensing speed (optional), Als 380 – Avery Dennison ALS 380 User Manual

Page 45: Peration, Etting, Monitoring, Dispensing speed (velo)

Advertising
background image

43

4

O

PERATION

4.2 S

ETTING

AND

MONITORING

ALS

380

4.2.3

Dispensing speed

(VELO)

As a rule, the labelling speed must correspond to the
product speed. Depending on the operating conditions,
the labelling speed can also be set somewhat higher in
unique cases.

Prerequisites:
– The label stop position (STOD) is correctly set.

In the standard menu, press the NEXT [43A] or
PRIOR [43B] key until VELO [44] is displayed on
the operator panel.

Call up the VELO function by pressing the
ENTER [43C] key.

– The current speed is displayed on the operator pan-

el in m/min.

Change the labelling speed using the NEXT or PRI-
OR key.

– Settings are permitted in steps of 0.1 m/min:

Minimum: 0.5 m/min
Maximum: 80 m/min (ALS 380 HS: to 100 m/min)

– Confirm the setting using the ENTER key and exit

the VELO function.

Test the setting:

Remove the pressure roller unit (optional) at the dis-
pensing edge.

Start the system and only label one product.

– The labelling speed is too low if the product pulls the

label away from the backing material.

– The labelling speed is too high if the label on the

product has folds in it.

Automatic dispensing speed (optional)

If the automatic dispensing speed (APSF) is activated:
– Only display of the current speed using the VELO

function.

– Manual setting of the dispensing speed is not possi-

ble.

– For further information on the APSF function, see

chapter Operation - Automatic dispensing speed.