Als 380 – Avery Dennison ALS 380 User Manual
Page 49

47
4.2 S
ETTING
AND
MONITORING
ALS
380
Error messages
If the machine control system detects a serious mal-
function:
– The labelling operation is automatically halted.
– An error message appears on the LED-indicator of
the operator panel.
– A warning message is displayed in the format E_nn:
E stands for error,
nn is a two-digit numerical code.
– An electronic signal is issued at the same time. The
signal can be further processed by an external con-
trol system.
– For an explanation of the error messages and notes
on fault elimination, see chapter Operational mal-
functions.
Example [51]:
– The label ribbon is torn.
– The error message E__6 appears on the operator
panel.
– An electronic signal is sent to the system control.
– The system control issues an additonal warning
tone and stops the conveyor belt.
[51] Example: The error message E__6 is displayed on the operator
panel