3 monitoring functions, Dispensing a label to each product, Label supply – Avery Dennison ALS 380 User Manual

Page 22: If errors occur, Als 380

Advertising
background image

20

2

E

QUIPMENT

DESCRIPTION

2.3 C

ONTROL

SYSTEM

ALS

380

2.3.3

Monitoring functions

During labelling operation, the electronic control sys-
tem and the sensors monitor the following functions.

Dispensing a label to each product

– A photoelectric sensor (product sensor) sends a sig-

nal when a product reaches the dispensing
edge [9B]. The signal from the product sensor trig-
gers the label feed for a single label.

– If individual labels are missing from the label ribbon,

the label feed compensates for this and advances
the label ribbon by one additional label distance (la-
bel compensation).

– If label compensation does not take place before the

next start signal of the product sensor, the product
does not get labelled. A warning message appears
at the operator panel.

– If the number of unlabelled products exceeds a cer-

tain value, the machine stops.

Label supply

– If no more labels arrive at the label stop sensor [9A]

[10A], the machine stops and sends a signal to the
output to the system controller.

– Install roll diameter control (optional):

If the diameter of the label roll on the unwinding
spool [9C] becomes too small, the control system
sends a warning message and a signal to the output
to the system controller. The diameter at which the
signal will be sent can be set by servicing techni-
cians.

If errors occur

If a malfunction occurs, the control system sends a cor-
responding message to the operator. If necessary, the
labelling operation is automatically halted. The ma-
chine simultaneously sends a signal to the system con-
troller.

[9] A Label stop sensor

B The product sensor sends a signal when the product has

reached the dispensing edge.

C Label roll on the unwinding spool

[10] Backing material with a label under the label stop sensor (A)

B

A

C

A

Advertising