Fine tuning of the dwell time (apt4), Als 380, Peration – Avery Dennison ALS 380 User Manual

Page 74: Pplicator, Optional

Advertising
background image

72

4

O

PERATION

4.6 A

PPLICATOR

(

OPTIONAL

)

ALS

380

Fine tuning of the dwell time (APT4)

When using an applicator in combination with the auto-
matic speed adjustment (APSF):
– Optimise the accuracy of the label position on the

product by fine tuning the dwell time for the applica-
tor.

Standard values:
– Blowing applicators: approx. 25 ms
– EP applicators: 60 ms … 100 ms, depending on the

length of the stroke

Prerequisite:
– External RPM transmitter is calibrated (EGRA func-

tion)

Determining and setting the exact value [74]:

Call up the APT4 function in the extended menu.

Set the setting value for APT4 to 1.

Allow the conveyor belt (with products) to run slowly.

– Speed v

N

= 10 m/min

Document the position of the label on the product:
Value: POS

N

in mm

Increase speed of the conveyor belt to approx.
25 m/min (value v

H

).

Document the position of the label on the product:
Value: POS

H

in mm

Calculating the setting value for APT4:

Input the calculated setting value.

Confirm the value using the ENTER key and exit
the function.

Test the setting:

Test the labelling accuracy at different conveyor belt
speeds.

If necessary, correct the setting value for APT4:

– The greater the value for APT4, the farther forward

the label is applied.

– The smaller the value for APT4, the farther to the

rear the label is applied.

[74] Label position in relation to the conveyor belt speed

v

N

- low conveyor belt speed

POS

N

- Label position at lower conveyor belt speed

v

H

- high conveyor belt speed

POS

H

- Label position at higher conveyor belt speed

Advertising